Part Number Hot Search : 
LRC10 CS330 VT83C469 D42S1716 MSK3017 GSIB810 KTY84 F1005
Product Description
Full Text Search
 

To Download CS61880-IB Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 CS61880 Octal E1 Line Interface Unit
Features
Octal E1 Short-haul Line Interface Unit Low Power No External Component Changes for 120 / 75 Operation Pulse Shapes can be customized by the user Internal AMI, or HDB3 Encoding/Decoding LOS Detection per ITU G.775 or ETSI 300- 233 G.772 Non-Intrusive Monitoring G.703 BITS Clock Recovery Crystal-less Jitter Attenuation Serial/Parallel Microprocessor Control Interfaces Transmitter Short Circuit Current Limiter (<50 mA) TX Drivers with Fast High-Z and Power Down JTAG Boundary Scan compliant to IEEE 1149.1 144-Pin LQFP or 160-Pin FBGA Package ORDERING INFORMATION CS61880-IQ CS61880-IB 144-pin LQFP 160-pin FBGA
Description
The CS61880 is a full-featured Octal E1 short-haul LIU that supports 2.048 Mbps data transmission for both E1 75 and E1 120 applications. Each channel provides crystal-less jitter attenuation that complies with the most stringent standards. Each channel also provides internal AMI/HDB3 encoding/decoding. To support enhanced system diagnostics, channel zero can be configured for G.772 non-intrusive monitoring of any of the other 7 channels' receive or transmit paths. The CS61880 makes use of ultra low power matched impedance transmitters and receivers to reduce power beyond that achieved by traditional driver designs. By achieving a more precise line match, this technique also provides superior return loss characteristics. Additionally, the internal line matching circuitry reduces the external component count. All transmitters have controls for independent power down and High-Z. Each receiver provides reliable data recovery with over 12 dB of cable attenuation. The receiver also incorporates LOS detection compliant to the most recent specifications.
LOS Decoder RCLK RPOS RNEG
LOS Receiver Clock Recovery Data Recovery RTIP Analog Loopback RRING G.772 Monitor Remote Loopback
Digital Loopback
Jitter Attenuator
Driver Transmit Control Pulse Shaper
TCLK TPOS TNEG
TTIP TRING
0 1 7 JTAG Serial Port JTAG Interface Host Interface Host Serial/Parallel Port
Preliminary Product Information
http://www.cirrus.com
Encoder
This document contains information for a new product. Cirrus Logic reserves the right to modify this product without notice.
Copyright Cirrus Logic, Inc. 2003 (All Rights Reserved)
JUL `03 DS450PP3 1
CS61880
TABLE OF CONTENTS
1. PIN OUT - 144-PIN LQFP PACKAGE ................................................................................... 7 2. PIN OUT - 160-BALL FBGA PACKAGE .................................................................................. 8 3. PIN DESCRIPTIONS ................................................................................................................ 9 3.1 Power Supplies .................................................................................................................. 9 3.2 Control ............................................................................................................................. 10 3.3 Address Inputs/Loopbacks ............................................................................................... 14 3.4 Cable Select .................................................................................................................... 15 3.5 Status ............................................................................................................................... 15 3.6 Digital Rx/Tx Data I/O ...................................................................................................... 16 3.7 Analog RX/TX Data I/O .................................................................................................... 19 3.8 JTAG Test Interface ......................................................................................................... 21 3.9 Miscellaneous .................................................................................................................. 21 4. OPERATION ........................................................................................................................... 22 5. POWER-UP ............................................................................................................................. 22 6. MASTER CLOCK ................................................................................................................... 22 7. G.772 MONITORING .............................................................................................................. 22 8. BUILDING INTEGRATED TIMING SYSTEMS (BITS) CLOCK MODE .................................. 23 9. TRANSMITTER ....................................................................................................................... 24 9.1 Bipolar Mode .................................................................................................................... 24 9.2 Unipolar Mode .................................................................................................................. 24 9.3 RZ Mode .......................................................................................................................... 25 9.4 Transmitter Powerdown / High-Z ..................................................................................... 25 9.5 Transmit All Ones (TAOS) ............................................................................................... 25 9.6 Automatic TAOS .............................................................................................................. 25 9.7 Driver Failure Monitor ...................................................................................................... 25 9.8 Driver Short Circuit Protection ......................................................................................... 25
Contacting Cirrus Logic Support
For all product questions and inquiries contact a Cirrus Logic Sales Representative. To find the one nearest to you go to: http://www.cirrus.com/
IMPORTANT NOTICE "Preliminary" product information describes products that are in production, but for which full characterization data is not yet available. Cirrus Logic, Inc. and its subsidiaries ("Cirrus") believe that the information contained in this document is accurate and reliable. However, the information is subject to change without notice and is provided "AS IS" without warranty of any kind (express or implied). Customers are advised to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgment, including those pertaining to warranty, patent infringement, and limitation of liability. No responsibility is assumed by Cirrus for the use of this information, including use of this information as the basis for manufacture or sale of any items, or for infringement of patents or other rights of third parties. This document is the property of Cirrus and by furnishing this information, Cirrus grants no license, express or implied under any patents, mask work rights, copyrights, trademarks, trade secrets or other intellectual property rights. Cirrus owns the copyrights associated with the information contained herein and gives consent for copies to be made of the information only for use within your organization with respect to Cirrus integrated circuits or other products of Cirrus. This consent does not extend to other copying such as copying for general distribution, advertising or promotional purposes, or for creating any work for resale. An export permit needs to be obtained from the competent authorities of the Japanese Government if any of the products or technologies described in this material and controlled under the "Foreign Exchange and Foreign Trade Law" is to be exported or taken out of Japan. An export license and/or quota needs to be obtained from the competent authorities of the Chinese Government if any of the products or technologies described in this material is subject to the PRC Foreign Trade Law and is to be exported or taken out of the PRC. CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE ("CRITICAL APPLICATIONS"). CIRRUS PRODUCTS ARE NOT DESIGNED, AUTHORIZED OR WARRANTED FOR USE IN AIRCRAFT SYSTEMS, MILITARY APPLICATIONS, PRODUCTS SURGICALLY IMPLANTED INTO THE BODY, LIFE SUPPORT PRODUCTS OR OTHER CRITICAL APPLICATIONS (INCLUDING MEDICAL DEVICES, AIRCRAFT SYSTEMS OR COMPONENTS AND PERSONAL OR AUTOMOTIVE SAFETY OR SECURITY DEVICES). INCLUSION OF CIRRUS PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMER'S RISK AND CIRRUS DISCLAIMS AND MAKES NO WARRANTY, EXPRESS, STATUTORY OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE, WITH REGARD TO ANY CIRRUS PRODUCT THAT IS USED IN SUCH A MANNER. IF THE CUSTOMER OR CUSTOMER'S CUSTOMER USES OR PERMITS THE USE OF CIRRUS PRODUCTS IN CRITICAL APPLICATIONS, CUSTOMER AGREES, BY SUCH USE, TO FULLY INDEMNIFY CIRRUS, ITS OFFICERS, DIRECTORS, EMPLOYEES, DISTRIBUTORS AND OTHER AGENTS FROM ANY AND ALL LIABILITY, INCLUDING ATTORNEYS' FEES AND COSTS, THAT MAY RESULT FROM OR ARISE IN CONNECTION WITH THESE USES. Cirrus Logic, Cirrus, and the Cirrus Logic logo designs are trademarks of Cirrus Logic, Inc. All other brand and product names in this document may be trademarks or service marks of their respective owners. Intel is a registered trademark of Intel Corporation. Motorola is a registered trademark of Motorola, Inc.
2
DS450PP3
CS61880
10. RECEIVER ............................................................................................................................ 26 10.1 Bipolar Output Mode ...................................................................................................... 26 10.2 Unipolar Output Mode ................................................................................................... 26 10.3 RZ Output Mode ............................................................................................................ 26 10.4 Receiver Powerdown/High-Z ......................................................................................... 27 10.5 Loss-of-Signal (LOS) ..................................................................................................... 27 10.6 Alarm Indication Signal (AIS) ......................................................................................... 27 11. JITTER ATTENUATOR ........................................................................................................ 28 12. OPERATIONAL SUMMARY ................................................................................................ 29 12.1 Loopbacks ..................................................................................................................... 29 12.2 Analog Loopback ........................................................................................................... 29 12.3 Digital Loopback ............................................................................................................ 30 12.4 Remote Loopback ......................................................................................................... 30 13. HOST MODE ........................................................................................................................ 32 13.1 SOFTWARE RESET ..................................................................................................... 32 13.2 Serial Port Operation ..................................................................................................... 32 13.3 Parallel Port Operation .................................................................................................. 33 13.4 Register Set ................................................................................................................... 34 14. REGISTER DESCRIPTIONS ................................................................................................ 35 14.1 Revision/IDcode Register (00h) ..................................................................................... 35 14.2 Analog Loopback Register (01h) ................................................................................... 35 14.3 Remote Loopback Register (02h) .................................................................................. 35 14.4 TAOS Enable Register (03h) ......................................................................................... 35 14.5 LOS Status Register (04h) ............................................................................................ 35 14.6 DFM Status Register (05h) ............................................................................................ 35 14.7 LOS Interrupt Enable Register (06h) ............................................................................. 36 14.8 DFM Interrupt Enable Register (07h) ............................................................................ 36 14.9 LOS Interrupt Status Register (08h) .............................................................................. 36 14.10 DFM Interrupt Status Register (09h) ........................................................................... 36 14.11 Software Reset Register (0Ah) .................................................................................... 36 14.12 Performance Monitor Register (0Bh) ........................................................................... 36 14.13 Digital Loopback Reset Register (0Ch) ....................................................................... 36 14.14 LOS/AIS Mode Enable Register (0Dh) ........................................................................ 37 14.15 Automatic TAOS Register (0Eh) .................................................................................. 37 14.16 Global Control Register (0Fh) ...................................................................................... 37 14.17 Line Length Channel ID Register (10h) ....................................................................... 38 14.18 Line Length Data Register (11h) ................................................................................. 38 14.19 Output Disable Register (12h) ..................................................................................... 38 14.20 AIS Status Register (13h) ............................................................................................ 38 14.21 AIS Interrupt Enable Register (14h) ............................................................................ 39 14.22 AIS Interrupt Status Register (15h) ............................................................................. 39 14.23 AWG Broadcast Register (16h) ................................................................................... 39 14.24 AWG Phase Address Register (17h) ........................................................................... 39 14.25 AWG Phase Data Register (18h) ................................................................................ 39 14.26 AWG Enable Register (19h) ........................................................................................ 40 14.27 Reserved Register (1Ah) ............................................................................................. 40 14.28 Reserved Register (1Bh) ............................................................................................. 40 14.29 Reserved Register (1Ch) ............................................................................................. 40 14.30 Reserved Register (1Dh) ............................................................................................. 40 14.31 Bits Clock Enable Register (1Eh) ................................................................................ 40 14.32 Reserved Register (1Fh) ............................................................................................. 40 14.33 Status Registers .......................................................................................................... 40 14.33.1 Interrupt Enable Registers .............................................................................. 41
DS450PP3
3
CS61880
14.33.2 Interrupt Status Registers ............................................................................... 41 15. ARBITRARY WAVEFORM GENERATOR ........................................................................... 42 16. JTAG SUPPORT .................................................................................................................. 43 16.1 TAP Controller ............................................................................................................... 44 16.1.1 JTAG Reset ....................................................................................................... 44 16.1.2 Test-Logic-Reset ............................................................................................... 44 16.1.3 Run-Test-Idle .................................................................................................... 44 16.1.4 Select-DR-Scan ................................................................................................ 44 16.1.5 Capture-DR ....................................................................................................... 44 16.1.6 Shift-DR ............................................................................................................. 44 16.1.7 Exit1-DR ............................................................................................................ 44 16.1.8 Pause-DR .......................................................................................................... 45 16.1.9 Exit2-DR ............................................................................................................ 45 16.1.10 Update-DR ...................................................................................................... 45 16.1.11 Select-IR-Scan ................................................................................................ 45 16.1.12 Capture-IR ....................................................................................................... 45 16.1.13 Shift-IR ............................................................................................................ 45 16.1.14 Exit1-IR ........................................................................................................... 46 16.1.15 Pause-IR ......................................................................................................... 46 16.1.16 Exit2-IR ........................................................................................................... 46 16.1.17 Update-IR ........................................................................................................ 46 16.2 Instruction Register (IR) ................................................................................................. 46 16.2.1 EXTEST ............................................................................................................ 46 16.2.2 SAMPLE/PRELOAD ......................................................................................... 46 16.2.3 IDCODE ............................................................................................................ 46 16.2.4 BYPASS ............................................................................................................ 46 16.3 Device ID Register (IDR) ............................................................................................... 47 17. BOUNDARY SCAN REGISTER (BSR) ................................................................................ 47 18. APPLICATIONS .................................................................................................................... 50 18.1 Transformer Specifications ............................................................................................ 52 18.2 Crystal Oscillator Specifications ..................................................................................... 52 18.3 Line Protection ............................................................................................................... 52 19. CHARACTERISTICS AND SPECIFICATIONS .................................................................... 53 19.1 Absolute Maximum Ratings ........................................................................................... 53 19.2 Recommended Operating Conditions ............................................................................ 53 19.3 Digital Characteristics .................................................................................................... 54 19.4 Transmitter Analog Characteristics ................................................................................ 54 19.5 Receiver Analog Characteristics .................................................................................... 55 19.6 Jitter Attenuator Characteristics ..................................................................................... 56 19.7 Master Clock Switching Characteristics ......................................................................... 58 19.8 Transmit Switching Characteristics ................................................................................ 58 19.9 Receive Switching Characteristics ................................................................................. 58 19.10 Switching Characteristics - Serial Port ......................................................................... 60 19.11 Switching Characteristics - Parallel Port (Multiplexed Mode) ..................................... 61 19.12 Switching Characteristics- Parallel Port (Non-Multiplexed Mode) ............................... 64 19.13 Switching Characteristics - JTAG ................................................................................ 67 20. COMPLIANT RECOMMENDATIONS AND SPECIFICATIONS .......................................... 68 21. 160-BALL FBGA PACKAGE DIMENSIONS ........................................................................ 69 22. 144-PIN LQFP PACKAGE DIMENSIONS ....................................................................... 70
4
DS450PP3
CS61880
LIST OF FIGURES
Figure 1. CS61880 144-Pin LQFP Package Pin Outs .................................................................... 7 Figure 2. CS61880 160-Ball FBGA Package Pin Outs ................................................................... 8 Figure 3. G.703 BITS Clock Mode in NRZ Mode .......................................................................... 23 Figure 4. G.703 BITS Clock Mode in RZ Mode............................................................................. 23 Figure 5. G.703 BITS Clock Mode in Remote Loopback .............................................................. 23 Figure 6. Pulse Mask at E1 Interface ............................................................................................ 24 Figure 7. Analog Loopback Block Diagram................................................................................... 30 Figure 8. Analog Loopback with TAOS Block Diagram................................................................. 30 Figure 9. Digital Loopback Block Diagram .................................................................................... 31 Figure 10. Digital Loopback with TAOS ........................................................................................ 31 Figure 11. Remote Loopback Block Diagram ............................................................................... 31 Figure 12. Serial Read/Write Format (SPOL = 0) ......................................................................... 33 Figure 13. Arbitrary Waveform UI ................................................................................................. 42 Figure 14. Test Access Port Architecture...................................................................................... 44 Figure 15. TAP Controller State Diagram ..................................................................................... 45 Figure 16. Internal RX/TX Impedance Matching ........................................................................... 50 Figure 17. Internal TX, External RX Impedance Matching............................................................ 51 Figure 18. Jitter Transfer Characteristic vs. G.736 & TBR 12/13 .................................................. 56 Figure 19. Jitter Tolerance Characteristic vs. G.823..................................................................... 57 Figure 20. Recovered Clock and Data Switching Characteristics................................................. 59 Figure 21. Transmit Clock and Data Switching Characteristics .................................................... 59 Figure 22. Signal Rise and Fall Characteristics ............................................................................ 59 Figure 23. Serial Port Read Timing Diagram ................................................................................ 60 Figure 24. Serial Port Write Timing Diagram ................................................................................ 60 Figure 25. Parallel Port Timing - Write; Intel(R) Multiplexed Address / Data Bus Mode ................. 62 Figure 26. Parallel Port Timing - Read; Intel Multiplexed Address / Data Bus Mode.................... 62 Figure 27. Parallel Port Timing - Write; Motorola(R) Multiplexed Address / Data Bus Mode .......... 63 Figure 28. Parallel Port Timing - Read; Motorola Multiplexed Address / Data Bus Mode............. 63 Figure 29. Parallel Port Timing - Write; Intel Non-Multiplexed Address / Data Bus Mode ............ 65 Figure 30. Parallel Port Timing - Read; Intel Non-Multiplexed Address / Data Bus Mode ............ 65 Figure 31. Parallel Port Timing - Write; Motorola Non-Multiplexed Address / Data Bus Mode ..... 66 Figure 32. Parallel Port Timing - Read; Motorola Non-Multiplexed Address / Data Bus Mode ..... 66 Figure 33. JTAG Switching Characteristics................................................................................... 67 Figure 34. 160-Ball FBGA Package Drawing................................................................................ 69 Figure 35. 144-Pin LQFP Package Drawing ................................................................................. 70
DS450PP3
5
CS61880
LIST OF TABLES
Table 1. Operation Mode Selection ............................................................................................... 10 Table 2. Mux/Bits Clock Selection ................................................................................................. 11 Table 3. Jitter Attenuation Selection.............................................................................................. 12 Table 4. Cable Impedance Selection ............................................................................................ 15 Table 5. Bipolar Mode Translations............................................................................................... 16 Table 6. G.772 Address Selection................................................................................................. 22 Table 7. Jitter Attenuator Configurations....................................................................................... 28 Table 8. Operational Summary ..................................................................................................... 29 Table 9. Host Control Signal Descriptions..................................................................................... 32 Table 10. Host Mode Register Set ................................................................................................ 34 Table 11. Jitter Attenuator Position Selection ............................................................................... 37 Table 12. Transmitter Pulse Shape Selection ............................................................................... 38 Table 13. JTAG Instructions.......................................................................................................... 46 Table 14. Boundary Scan Register ............................................................................................... 47 Table 15. Transformer Specifications............................................................................................ 52 Table 16. 144-Pin Package Dimensions ....................................................................................... 70
6
DS450PP3
CS61880
1. PIN OUT - 144-PIN LQFP PACKAGE
144 143 142 141 140 139 138 137 136 135 134 133 132 131 130 129 128 127 126 125 124 123 122 121 120 119 118 117 116 115 114 113 112 111 110 109
108 107 106 105 104 103 102 101 100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76 75 74 73
TNEG7/UBS7 RCLK7 RPOS7/RDATA7 RNEG7/BPV7 LOS7 RTIP7 RRING7 TV+7 TTIP7 TRING7 TGND7 RRING6 RTIP6 TGND6 TRING6 TTIP6 TV+6 RTIP5 RRING5 TV+5 TTIP5 TRING5 TGND5 RRING4 RTIP4 TGND4 TRING4 TTIP4 TV+4 CLKE TXOE LOS4 RNEG4/BPV4 RPOS4/RDATA4 RCLK4 TNEG4/UBS4
TPOS7/TDATA7 TCLK7 LOS6 RNEG6/BPV6 RPOS6/RDATA6 RCLK6 TNEG6/UBS6 TPOS6/TDATA6 TCLK6 MCLK MODE A4 A3 A2 A1 A0 VCCIO GNDIO RV0+ RGND0 LOOP0/D0 LOOP1/D1 LOOP2/D2 LOOP3/D3 LOOP4/D4 LOOP5/D5 LOOP6/D6 LOOP7/D7 TCLK1 TPOS1/TDATA1 TNEG1/UBS1 RCLK1 RPOS1/RDATA1 RNEG1/BPV1 LOS1 TCLK0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
26
CS61880 144-Pin LQFP (Top View)
27 28 29
30
31 32
33
34
35
36
37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72
TPOS4/TDATA4 TCLK4 LOS5 RNEG5/BPV5 RPOS5/RDATA5 RCLK5 TNEG5/UBS5 TPOS5/TDATA5 TCLK5 TDI TDO TCK TMS TRST REF CBLSEL VCCIO GNDIO RV1+ RGND1 INTL/MOT/CODEN CS/JASEL ALE/AS/SCLK RD/RW WR/DS/SDI RDY/ACK/SDO INT TCLK2 TPOS2/TDATA2 TNEG2/UBS2 RCLK2 RPOS2/RDATA2 RNEG2/BPV2 LOS2 TCLK3 TPOS3/TDATA3
DS450PP3
TPOS0/TDATA0 TNEG0/USB0 RCLK0 RPOS0/RDATA0 RNEG0/BPV0 LOS0 MUX/BITSEN0 TV+0 TTIP0 TRING0 TGND0 RTIP0 RRING0 TGND1 TRING1 TTIP1 TV+1 RRING1 RTIP1 TV+2 TTIP2 TRING2 TGND2 RTIP2 RRING2 TGND3 TRING3 TTIP3 TV+3 RRING3 RTIP3 LOS3 RNEG3/RBPV3 RPOS3/RDATA3 RCLK3 TNEG3/UBS3
Figure 1. CS61880 144-Pin LQFP Package Pin Outs
7
CS61880
2. PIN OUT - 160-BALL FBGA PACKAGE
14 A B C D E F G H J K L M N P
RCLK 4 TCLK 4
13
RPOS 4 TPOS 4
12
RNEG 4 TNEG 4
11
TVCC 4 TVCC 4
10
TRING 4 TTIP 4
9
TGND 4 TGND 4
8
RTIP 4 RRING 4
7
RTIP 7 RRING 7
6
TGND 7 TGND 7
5
TRING 7 TTIP 7
4
TVCC 7 TVCC 7
3
RNEG 7 TNEG 7
2
RPOS 7 TPOS 7
1
RCLK 7 TCLK 7
A B C D E F G H J K L M N P
RCLK 5
RPOS 5
RNEG 5
TVCC 5
TRING 5
TGND 5
RTIP 5
RTIP 6
TGND 6
TRING 6
TVCC 6
RNEG 6
RPOS 6
RCLK 6
TCLK 5
TPOS 5
TNEG 5
TVCC 5
TTIP 5
TGND 5
RRING 5
RRING 6
TGND 6
TTIP 6
TVCC 6
TNEG 6
TPOS 6
TCLK 6
TXOE
CLKE
LOS 5
LOS 4
LOS 7
LOS 6
MODE
MCLK
TCK
TDO
TDI
TMS
A4
A3
A2
A1
VCCIO
CBLSEL
TRST
GNDIO
RV1+
REF
INTL
RGND 1
CS61880 160 FBGA (Bottom View)
GNDIO
A0
LOOP 0 LOOP 2
VCCIO
RGND 0
LOOP 1
RV0+
WR
RD
ALE
CS
LOOP 3 LOS 0 TTIP 2 TGND 2 RRING 2 RRING 1 TGND 1 TTIP 1
LOOP 4 LOS 1
LOOP 5
LOOP 6 LOOP 7
RDY
INT
LOS 2 TNEG 2
LOS 3 TVCC 2
MUX
TCLK 2
TPOS 2
TVCC 1
TNEG 1
TPOS 1
TCLK 1
RCLK 2
RPOS 2
RNEG 2
TVCC 2
TRING 2
TGND 2
RTIP 2
RTIP 1
TGND 1
TRING 1
TVCC 1
RNEG 1
RPOS 1
RCLK 1
TCLK 3 RCLK 3
TPOS 3 RPOS 3
TNEG 3 RNEG 3
TVCC 3 TVCC 3
TTIP 3 TRING 3
TGND 3 TGND 3
RRING 3 RTIP 3
RRING 0 RTIP 0
TGND 0 TGND 0
TTIP 0 TRING 0
TVCC 0 TVCC 0
TNEG 0 RNEG 0
TPOS 0 RPOS 0
TCLK 0 RCLK 0
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Figure 2. CS61880 160-Ball FBGA Package Pin Outs
8
DS450PP3
CS61880
3. PIN DESCRIPTIONS 3.1 Power Supplies
SYMBOL VCCIO GNDIO RV0+ RV1+ RGND0 RGND1 TV+0 TGND0 TV+1 TGND1 TV+2 TGND2 TV+3 TGND3 TV+4 TGND4 TV+5 TGND5 TV+6 TGND6 TV+7 TGND7 LQFP 17 92 18 91 19 90 20 89 44 47 53 50 56 59 65 62 116 119 125 122 128 131 137 134 FBGA G1 G14 G4 G11 H1 H14 H4 H11 N4, P4 N6, P6 L4, M4 L6, M6 L11 M11 L9, M9 N11 P11 N9, P9 A11 B11 A9, B9 C11 D11 C9, D9 C4, D4 C6, D6 A4, B4 A6, B6 TYPE DESCRIPTION Power Supply, Digital Interface: Power supply for digital interface pins; typically 3.3 V Ground, Digital Interface: Power supply ground for the digital interface; typically 0 V Power Supply, Core Circuitry: Power supply for all sub-circuits except the transmit driver; typically +3.3 V Ground, Core Circuitry: Ground for sub-circuits except the TX driver; typically 0 V Power Supply, Transmit Driver 0 Power supply for transmit driver 0; typically +3.3 V Ground, Transmit Driver 0 Power supply ground for transmit driver 0; typically 0 V Power Supply, Transmit Driver 1 Ground, Transmit Driver 1 Power Supply, Transmit Driver 2 Ground, Transmit Driver 2 Power Supply, Transmit Driver 3 Ground, Transmit Driver 3 Power Supply, Transmit Driver 4 Ground, Transmit Driver 4 Power Supply, Transmit Driver 5 Ground, Transmit Driver 5 Power Supply, Transmit Driver 6 Ground, Transmit Driver 6 Power Supply, Transmit Driver 7 Ground, Transmit Driver 7
DS450PP3
9
CS61880
3.2 Control
SYMBOL LQFP FBGA TYPE DESCRIPTION Master Clock Input This pin is a free running reference clock that should be 2.048 MHz. This timing reference is used as follows: - Timing reference for the clock recovery and jitter attenuation circuitry. - RCLK reference during Loss of Signal (LOS) conditions - Transmit clock reference during Transmit all Ones (TAOS) condition - Wait state timing for microprocessor interface - When this pin is held "High", the PLL clock recovery circuit is disabled. In this mode, the CS61880 receivers function as simple data slicers. - When this pin is held "Low", the receiver paths are powered down and the output pins RCLK, RPOS, and RNEG are High-Z. Mode Select This pin is used to select whether the CS61880 operates in Serial host, Parallel host or Hardware mode. Host Mode - The CS61880 is controlled through either a serial or a parallel microprocessor interface (Refer to HOST MODE (See Section 13 on page 32). Hardware Mode - The microprocessor interface is disabled and the device control/status are provided through the pins on the device. MODE 11 E2 I Table 1. Operation Mode Selection Pin State LOW HIGH VCCIO/2 OPERATING Mode Hardware Mode Parallel Host Mode Serial Host Mode
MCLK
10
E1
I
NOTE: For serial host mode connect this pin to a resistor divider consisting of two 10 k resistors between VCCIO and GNDIO.
10
DS450PP3
CS61880
SYMBOL LQFP FBGA TYPE DESCRIPTION Multiplexed Interface/Bits Clock Select Host Mode -This pin configures the microprocessor interface for multiplexed or non-multiplexed operation. Hardware mode - This pin is used to enable channel 0 as a G.703 BITS Clock recovery channel (Refer to BUILDING INTEGRATED TIMING SYSTEMS (BITS) CLOCK MODE (See Section 8 on page 23). Channel 1 through 7 are not affected by this pin during hardware mode. During host mode the G.703 BITS Clock recovery function is enabled by the Bits Clock Enable Register (1Eh) (See Section 14.31 on page 40). Table 2. Mux/Bits Clock Selection Pin State HIGH LOW Parallel Host Mode multiplexed non multiplexed Hardware Mode BITS Clock ON BITS Clock OFF
MUX/BITSEN0
43
K2
I
NOTE: The MUX pin only controls the BITS Clock function in Hardware Mode Interrupt Output This active low output signals the host processor when one of the CS61880's internal status register bits has changed state. When the status register is read, the interrupt is cleared. The various status changes that would force INT active are maskable via internal interrupt enable registers. NOTE: This pin is an open drain output and requires a 10 k pull-up resistor. Ready/Data Transfer Acknowledge/Serial Data Output Intel Parallel Host Mode - During a read or write register access, RDY is asserted "Low" to acknowledge that the device has been accessed. An asserted "High" acknowledges that data has been written or read. Upon completion of the bus cycle, this pin High-Z. Motorola Parallel Host Mode - During a data bus read operation this pin, "ACK", is asserted "High" to indicate that data on the bus is valid. An asserted "Low" on this pin during a write operation acknowledges that a data transfer to the addressed register has been accepted. Upon completion of the bus cycle, this pin High-Z. NOTE: Wait state generation via RDY/ACK is disabled in RZ mode (No Clock Recovery). Serial Host Mode - When the microprocessor interface is configured for serial bus operation, "SDO" is used as a serial data output. This pin is forced into a high impedance state during a serial write access. The CLKE pin controls whether SDO is valid on the rising or falling edge of SCLK. Upon completion of the bus cycle, this pin High-Z. Hardware Mode - This pin is not used and should be left open.
INT
82
K13
O
RDY/ACK/SDO
83
K14
O
DS450PP3
11
CS61880
SYMBOL LQFP FBGA TYPE DESCRIPTION Write Enable/Data Strobe/Serial Data Intel Parallel Host Mode - This pin, "WR", functions as a write enable. Motorola Parallel Host Mode - This pin, "DS", functions as a data strobe input. Serial Host Mode - This pin, "SDI", functions as the serial data input. Hardware Mode - This pin is not used and should be connected to ground. Read Enable/Read/Write Intel Parallel Host Mode - This pin, "RD", functions as a read enable. Motorola Parallel Host Mode - This pin, "R/W", functions as the read/write input signal. Hardware Mode - This pin is not used and should be connected to ground. Address Latch Enable/Address Strobe/Serial Clock Intel Parallel Host Mode - This pin, "ALE", functions as the Address Latch Enable when configured for multiplexed address/data operation. Motorola Parallel Host Mode - This pin, "AS", functions as the active "low" address strobe when configured for multiplexed address/data operation. Serial Host Mode - This pin, "SCLK", is the serial clock used for data I/O on SDI and SDO. Hardware Mode - This pin is not used and should be connected to ground. Chip Select Input/Jitter Attenuator Select Host Mode - This active low input is used to enable accesses to the microprocessor interface in either serial or parallel mode. Hardware Mode - This pin controls the position of the Jitter Attenuator. Table 3. Jitter Attenuation Selection Pin State LOW HIGH OPEN Jitter Attenuation Position Transmit Path Receive Path Disabled
WR/DS/SDI
84
J14
I
RD/RW
85
J13
I
ALE/AS/SCLK
86
J12
I
CS/JASEL
87
J11
I
12
DS450PP3
CS61880
SYMBOL LQFP FBGA TYPE DESCRIPTION Intel/Motorola/Coder Mode Select Input Parallel Host Mode - When this pin is "Low" the microprocessor interface is configured for operation with Motorola processors. When this pin is "High" the microprocessor interface is configured for operation with Intel processors. Hardware Mode - When the CS61880 is configured for unipolar operation, this pin, CODEN, configures the line encoding/decoding function. When CODEN is low, HDB3 encoders/decoders are enabled. When CODEN is high, AMI encoding/decoding is activated. This is done for all eight channels. Transmitter Output Enable Host mode - Operates the same as in hardware mode. Individual drivers can be set to a high impedance state via the Output Disable Register (12h) (See Section 14.19 on page 38). Hardware Mode - When TXOE pin is asserted Low, all the TX drivers are forced into a high impedance state. All other internal circuitry remains active. Clock Edge Select In clock/data recovery mode, setting CLKE "high" will cause RPOS/RNEG to be valid on the falling edge of RCLK and SDO to be valid on the rising edge of SCLK. When CLKE is set "low", RPOS/RNEG is valid on the rising edge of RCLK, and SDO is valid on the falling edge of SCLK. When the part is operated in data recovery mode, the RPOS/RNEG output polarity is active "high" when CLKE is set "high" and active "low" when CLKE is set "low".
INTL/MOT/CODEN
88
H12
I
TXOE
114
E14
I
CLKE
115
E13
I
DS450PP3
13
CS61880
3.3 Address Inputs/Loopbacks
SYMBOL LQFP FBGA TYPE DESCRIPTION Address Selector Input Parallel Host Mode - During non-multiplexed parallel host mode operation, this pin function as the address 4 input for the parallel interface. Hardware Mode - The A4 pin must be tied low at all times. Non-Intrusive Monitoring/Address Selector Inputs Parallel Host Mode - During non-multiplexed parallel host mode operation, these pins function as address A[3:0] inputs for the parallel interface. Hardware Mode - The A[3:0] pins are used for port selection during non-intrusive monitoring. In non-intrusive monitoring mode, receiver 0's input is internally connected to the transmit or receive ports on one of the other 7 channels. The recovered clock and data from the selected port are output on RPOS0/RNEG0 and RCLK0. Additionally, the data from the selected port can be output on TTIP0/TRING0 by activating the remote loopback function for channel 0 (Refer to Performance Monitor Register (0Bh) (See Section 14.12 on page 36). Loopback Mode Selector/Parallel Data Input/Output Parallel Host Mode - In non-multiplexed microprocessor interface mode, these pins function as the bi-directional 8-bit data port. When operating in multiplexed microprocessor interface mode, these pins function as the address and data inputs/outputs. Hardware Mode - No Loopback - The CS61880 is in a normal operating state when LOOP is left open (unconnected) or tied to VCCIO/2. - Local Loopback - When LOOP is tied High, data transmitted on TTIP and TRING is looped back into the analog input of the corresponding channel's receiver and output on RPOS and RNEG. Input Data present on RTIP and RRING is ignored. - Remote Loopback - When LOOP is tied Low the recovered clock and data received on RTIP and RRING is looped back for transmission on TTIP and TRING. Data on TPOS and TNEG is ignored.
A4
12
F4
I
A3 A2 A1 A0
13 14 15 16
F3 F2 F1 G3
I I I I
LOOP0/D0 LOOP1/D1 LOOP2/D2 LOOP3/D3 LOOP4/D4 LOOP5/D5 LOOP6/D6 LOOP7/D7
21 22 23 24 25 26 27 28
G2 H3 H2 J4 J3 J2 J1 K1
I/O I/O I/O I/O I/O I/O I/O I/O
14
DS450PP3
CS61880
3.4 Cable Select
SYMBOL LQFP FBGA TYPE DESCRIPTION Cable Impedance Select Host Mode - The input voltage to this pin does not effect normal operation. Hardware Mode - This pin is used to select the transmitted pulse shape and set the line impedance for all eight receivers and transmitters. This pin also selects whether or not all eight receivers use an internal or external line matching network (Refer to the Table 4 below for proper settings).
Table 4. Cable Impedance Selection CBLSEL 93 G13 I CBLSEL No Connect HIGH LOW Transmitters 120 Internal 75 Internal 75 Internal Receivers 120 Internal or External 75 Internal 75 External
NOTE: Refer to Figure 16 on page 50 and Figure 17 on page 51 for appropriate external line matching components. All transmitters use internal matching networks.
3.5 Status
SYMBOL LOS0 LOS1 LOS2 LOS3 LOS4 LOS5 LOS6 LOS7 LQFP 42 35 75 68 113 106 3 140 FBGA K4 K3 K12 K11 E11 E12 E3 E4 TYPE O O O O O O O O DESCRIPTION Loss of Signal Output The LOS output pins can be configured to indicate a loss of signal (LOS) state that is compliant to either ITU G.775 or ETSI 300 233. These pins are asserted "High" to indicate LOS. The LOS output returns low when an input signal is present for the time period dictated by the associated specification (Refer to Loss-of-Signal (LOS) (See Section 10.5 on page 27)).
DS450PP3
15
CS61880
3.6 Digital Rx/Tx Data I/O
SYMBOL LQFP FBGA TYPE DESCRIPTION Transmit Clock Input Port 0 - When TCLK is active, the TPOS and TNEG pins function as NRZ inputs that are sampled on the falling edge of TCLK. - If MCLK is active, TAOS will be generated when TCLK is held High for 16 MCLK cycles. TCLK0 36 N1 I NOTE: MCLK is used as the timing reference during TAOS and must have the appropriate stability. - If TCLK is held High in the absence of MCLK, the TPOS and TNEG inputs function as RZ inputs. In this mode, the transmit pulse width is set by the pulse-width of the signal input on TPOS and TNEG. To enter this mode, TCLK must be held high for at least 12 s. - If TCLK is held Low, the output drivers enter a low-power, high impedance state. Transmit Positive Pulse/Transmit Data Input Port 0 Transmit Negative Pulse/Unipolar-Bipolar Select Port 0 The function of the TPOS/TDATA and TNEG/UBS inputs are determined by whether Unipolar, Bipolar or RZ input mode has been selected. Bipolar Mode - In this mode, NRZ data on TPOS and TNEG are sampled on the falling edge of TCLK and transmitted onto the line at TTIP and TRING respectively. A "High" input on TPOS results in transmission of a positive pulse; a "High" input on TNEG results in a transmission of a negative pulse. The translation of TPOS/TNEG inputs to TTIP/TRING outputs is as follows: TPOS0/TDATA0 TNEG0/UBS 37 38 N2 N3 I I TPOS 0 1 0 1 Table 5. Bipolar Mode Translations TNEG 0 0 1 1 OUTPUT Space Positive Mark Negative Mark Space
Unipolar mode - Unipolar mode is activated by holding TNEG/UBS "High" for more than 16 TCLK cycles, when MCLK is present. The falling edge of TCLK samples a unipolar data steam on TPOS/TDATA. RZ Mode - To activate RZ mode tie TCLK "High" in the absence of MCLK. In this mode, the duty cycle of the TPOS and TNEG inputs determine the pulse width of the output signal on TTIP and TRING.
16
DS450PP3
CS61880
SYMBOL LQFP FBGA TYPE DESCRIPTION Receive Clock Output Port 0 - When MCLK is active, this pin outputs the recovered clock from the signal input on RTIP and RRING. In the event of LOS, the RCLK output transitions from the recovered clock to MCLK. - If MCLK is held "High", the clock recovery circuitry is disabled and the RCLK output is driven by the XOR of RNEG and RPOS. - If MCLK is held "Low", this output is in a high-impedance state. Receive Positive Pulse/ Receive Data Output Port 0 Receive Negative Pulse/Bipolar Violation Output Port 0 The function of the RPOS/RDATA and RNEG/BPV outputs are determined by whether Unipolar, Bipolar, or RZ input mode has been selected. During LOS, the RPOS/RNEG outputs will remain active. NOTE: The RPOS/RNEG outputs can be High-Z by holding MCLK Low. RPOS0/RDATA0 RNEG0/BPV0 40 41 P2 P3 O O Bipolar Output Mode - When configured for Bipolar operation, NRZ Data is recovered from RTIP/RRING and output on RPOS/RNEG. A high signal on RPOS or RNEG correspond to the receipt of a positive or negative pulse on RTIP/RRING respectively. The RPOS/RNEG outputs are valid on the falling or rising edge of RCLK as configured by CLKE. Unipolar Output Mode - When unipolar mode is activated, the recovered data is output on RDATA. The decoder signals bipolar violations are output on the RNEG/BPV pin. RZ Output Mode - In this mode, the RPOS/RNEG pins output RZ data recovered by slicing the signal present on RTIP/RRING. A positive pulse on RTIP with respect to RRING generates a logic 1 on RPOS; a positive pulse on RRING with respect to RTIP generates a logic 1 on RNEG. The polarity of the output on RPOS/RNEG is selectable using the CLKE pin. In this mode, external circuitry is used to recover clock from the received signal. Transmit Clock Input Port 1 Transmit Positive Pulse/Transmit Data Input Port 1 Transmit Negative Pulse/Unipolar-Bipolar Select Port 1 Receive Clock Output Port 1 Receive Positive Pulse/ Receive Data Output Port 1 Receive Negative Pulse/Bipolar Violation Output Port 1 Transmit Clock Input Port 2 Transmit Positive Pulse/Transmit Data Input Port 2 Transmit Negative Pulse/Unipolar-Bipolar Select Port 2 17
RCLK0
39
P1
O
TCLK1 TPOS1/TDATA1 TNEG1/UBS1 RCLK1 RPOS1/RDATA1 RNEG1/BPV1 TCLK2 TPOS2/TDATA2 TNEG2/UBS2 DS450PP3
29 30 31 32 33 34 81 80 79
L1 L2 L3 M1 M2 M3 L14 L13 L12
I I I O O O I I I
CS61880
SYMBOL RCLK2 RPOS2/RDATA2 RNEG2/BPV2 TCLK3 TPOS3/TDATA3 TNEG3/UBS3 RCLK3 RPOS3/RDATA3 RNEG3/BPV3 TCLK4 TPOS4/TDATA4 TNEG4/UBS4 RCLK4 RPOS4/RDATA4 RNEG4/BPV4 TCLK5 TPOS5/TDATA5 TNEG5/UBS5 RCLK5 RPOS5/RDATA5 RNEG5/BPV5 TCLK6 TPOS6/TDATA6 TNEG6/UBS6 RCLK6 RPOS6/RDATA6 RNEG6/BPV6 TCLK7 TPOS7/TDATA7 TNEG7/UBS7 LQFP 78 77 76 74 73 72 71 70 69 107 108 109 110 111 112 100 101 102 103 104 105 9 8 7 6 5 4 2 1 144 FBGA M14 M13 M12 N14 N13 N12 P14 P13 P12 B14 B13 B12 A14 A13 A12 D14 D13 D12 C14 C13 C12 D1 D2 D3 C1 C2 C3 B1 B2 B3 TYPE O O O I I I O O O I I I O O O I I I O O O I I I O O O I I I DESCRIPTION Receive Clock Output Port 2 Receive Positive Pulse/ Receive Data Output Port 2 Receive Negative Pulse/Bipolar Violation Output Port 2 Transmit Clock Input Port 3 Transmit Positive Pulse/Transmit Data Input Port 3 Transmit Negative Pulse/Unipolar-Bipolar Select Port 3 Receive Clock Output Port 3 Receive Positive Pulse/ Receive Data Output Port 3 Receive Negative Pulse/Bipolar Violation Output Port 3 Transmit Clock Input Port 4 Transmit Positive Pulse/Transmit Data Input Port 4 Transmit Negative Pulse/Unipolar-Bipolar Select Port 4 Receive Clock Output Port 4 Receive Positive Pulse/ Receive Data Output Port 4 Receive Negative Pulse/Bipolar Violation Output Port 4 Transmit Clock Input Port 5 Transmit Positive Pulse/Transmit Data Input Port 5 Transmit Negative Pulse/Unipolar-Bipolar Select Port 5 Receive Clock Output Port 5 Receive Positive Pulse/ Receive Data Output Port 5 Receive Negative Pulse/Bipolar Violation Output Port 5 Transmit Clock Input Port 6 Transmit Positive Pulse/Transmit Data Input Port 6 Transmit Negative Pulse/Unipolar-Bipolar Select Port 6 Receive Clock Output Port 6 Receive Positive Pulse/ Receive Data Output Port 6 Receive Negative Pulse/Bipolar Violation Output Port 6 Transmit Clock Input Port 7 Transmit Positive Pulse/Transmit Data Input Port 7 Transmit Negative Pulse/Unipolar-Bipolar Select Port 7
18
DS450PP3
CS61880
SYMBOL RCLK7 RPOS7/RDATA7 RNEG7/BPV7 LQFP 143 142 141 FBGA A1 A2 A3 TYPE O O O DESCRIPTION Receive Clock Output Port 7 Receive Positive Pulse/ Receive Data Output Port 7 Receive Negative Pulse/Bipolar Violation Output Port 7
3.7 Analog RX/TX Data I/O
SYMBOL LQFP FBGA TYPE DESCRIPTION Transmit Tip Output Port 0 Transmit Ring Output Port 0 These pins are the differential outputs of the transmit driver. The driver internally matches impedances for E1 75 or E1 120 lines requiring only a 1:1.15 transformer. The CBLSEL pin is used to select the appropriate line matching impedance only in "Hardware" mode. In host mode, the appropriate line matching impedance is selected by the Line Length Data Register (11h) (See Section 14.18 on page 38). NOTE: TTIP and TRING are forced to a high impedance state when the TCLK or the TXOE pin is forced "Low". Receive Tip Input Port 0 Receive Ring Input Port 0 These pins are the differential line inputs to the receiver. The receiver uses either Internal Line Impedance or External Line Impedance modes to match the line impedances for E1 75 or E1 120 modes. Internal Line Impedance Mode - The receiver uses the same external resistors to match the line impedance (Refer to Figure 16 on page 50). External Line Impedance Mode - The receiver uses different external resistors to match the line impedance (Refer to Figure 17 on page 51). - In host mode, the appropriate line impedance is selected by the Line Length Data Register (11h) (See Section 14.18 on page 38). - In hardware mode, the CBLSEL pin selects the appropriate line impedance. (Refer to Table 4 on page 15 for proper line impedance settings). NOTE: Data and clock recovered from the signal input on these pins are output via RCLK, RPOS, and RNEG. TTIP1 TRING1 RTIP1 RRING1 TTIP2 52 51 55 54 57 L5 M5 M7 L7 L10 O O I I O Transmit Tip Output Port 1 Transmit Ring Output Port 1 Receive Tip Input Port 1 Receive Ring Input Port 1 Transmit Tip Output Port 2
TTIP0 TRING0
45 46
N5 P5
O O
RTIP0 RRING0
48 49
P7 N7
I I
DS450PP3
19
CS61880
SYMBOL TRING2 RTIP2 RRING2 TTIP3 TRING3 RTIP3 RRING3 TTIP4 TRING4 RTIP4 RRING4 TTIP5 TRING5 RTIP5 RRING5 TTIP6 TRING6 RTIP6 RRING6 TTIP7 TRING7 RTIP7 RRING7 LQFP 58 60 61 64 63 67 66 117 118 120 121 124 123 127 126 129 130 132 133 136 135 139 138 FBGA M10 M8 L8 N10 P10 P8 N8 B10 A10 A8 B8 D10 C10 C8 D8 D5 C5 C7 D7 B5 A5 A7 B7 TYPE O I I O O I I O O I I O O I I O O I I O O I I DESCRIPTION Transmit Ring Output Port 2 Receive Tip Input Port 2 Receive Ring Input Port 2 Transmit Tip Output Port 3 Transmit Ring Output Port 3 Receive Tip Input Port 3 Receive Ring Input Port 3 Transmit Tip Output Port 4 Transmit Ring Output Port 4 Receive Tip Input Port 4 Receive Ring Input Port 4 Transmit Tip Output Port 5 Transmit Ring Output Port 5 Receive Tip Input Port 5 Receive Ring Input Port 5 Transmit Tip Output Port 6 Transmit Ring Output Port 6 Receive Tip Input Port 6 Receive Ring Input Port 6 Transmit Tip Output Port 7 Transmit Ring Output Port 7 Receive Tip Input Port 7 Receive Ring Input Port 7
20
DS450PP3
CS61880
3.8 JTAG Test Interface
SYMBOL TRST LQFP 95 FBGA G12 TYPE I DESCRIPTION JTAG Reset This active Low input resets the JTAG controller. This input is pulled up internally and may be left as a NC when not used. JTAG Test Mode Select Input This input enables the JTAG serial port when active High. This input is sampled on the rising edge of TCK. This input is pulled up internally and may be left as a NC when not used. JTAG Test Clock Data on TDI is valid on the rising edge of TCK. Data on TDO is valid on the falling edge of TCK. When TCK is stopped high or low, the contents of all JTAG registers remain unchanged. Tie pin low through a 10 k resistor when not used. JTAG Test Data Output JTAG test data is shifted out of the device on this pin. Data is output on the falling edge of TCK. Leave as NC when not used. JTAG Test Data Input JTAG test data is shifted into the device using this pin. The pin is sampled on the rising edge of TCK. TDI is pulled up internally and may be left as a NC when not used.
TMS
96
F11
I
TCK
97
F14
I
TDO
98
F13
O
TDI
99
F12
I
3.9 Miscellaneous
SYMBOL REF LQFP 94 FBGA H13 TYPE I DESCRIPTION Reference Input This pin must be tied to ground through 13.3 k 1% resistor. This pin is used to set the internal current level.
DS450PP3
21
CS61880
4. OPERATION
The CS61880 is a full featured line interface unit for up to eight E1 75 or E1 120 lines. The device provides an interface to twisted pair or co-axial media. A matched impedance technique is employed that reduces power and eliminates the need for matching resistors. As a result, the device can interface directly to the line through a transformer without the need for matching resistors on the transmit side. The receive side uses the same resistor values for all E1 settings.
7. G.772 MONITORING
The receive path of channel zero of the CS61880 can be used to monitor the receive or transmit paths of any of the other channels. The signal to be monitored is multiplexed to channel zero through the G.772 Multiplexer. The multiplexer and channel zero then form a G.772 compliant digital Protected Monitoring Point (PMP). When the PMP is connected to the channel, the attenuation in the signal path is negligible across the signal band. The signal can be observed using RPOS, RNEG, and RCLK of channel zero or by putting channel zero in remote loopback, the signal can be observed on TTIP and TRING of channel zero. The G.772 monitoring function is available during both host mode and hardware mode operation. In host modes, individual channels are selected for monitoring via the Performance Monitor Register (0Bh) (See Section 14.12 on page 36)). In hardware mode, individual channels are selected through the A3:A0 pins (Refer to Table 6 below for address settings).
Table 6. G.772 Address Selection Address [A3:A0] 0000 0001 0010 0011 0100 0101 0110 0111 1000 1001 1010 1011 1100 1101 1110 1111 Channel Selection Monitoring Disabled Receiver Channel # 1 Receiver Channel # 2 Receiver Channel # 3 Receiver Channel # 4 Receiver Channel # 5 Receiver Channel # 6 Receiver Channel # 7 Monitoring Disabled Transmitter Channel # 1 Transmitter Channel # 2 Transmitter Channel # 3 Transmitter Channel # 4 Transmitter Channel # 5 Transmitter Channel # 6 Transmitter Channel # 7
5. POWER-UP
On power-up, the device is held in a static state until the power supply achieves approximately 70% of the power supply voltage. Once the power supply threshold is passed, the analog circuitry is calibrated, the control registers are reset to their default settings, and the various internal state machines are reset. The reset/calibration process completes in about 30 ms.
6. MASTER CLOCK
The CS61880 requires a 2.048 MHz reference clock with a minimum accuracy of 100 ppm. This clock may be supplied from internal system timing or a CMOS crystal oscillator and input to the MCLK pin. The receiver uses MCLK as a reference for clock recovery, jitter attenuation, and the generation of RCLK during LOS. The transmitter uses MCLK as the transmit timing reference during a blue alarm transmit all ones condition. In addition, MCLK provides the reference timing for wait state generation. In systems with a jittered transmit clock, MCLK should not be tied to the transmit clock, a separate crystal oscillator should drive the reference clock input. Any jitter present on the reference clock will not be filtered by the jitter attenuator and can cause the CS61880 to operate incorrectly.
NOTE: In hardware mode the A4 pin must be tied low at all times.
22
DS450PP3
CS61880
8. BUILDING INTEGRATED TIMING SYSTEMS (BITS) CLOCK MODE
This mode is used to enable one or more channels as a stand-alone timing recovery unit used for G.703 Clock Recovery. In hardware mode, BITS Clock mode is selected by pulling the MUX pin "HIGH". This enables only channel zero as a stand-alone timing recovery unit, no other channel can be used as a timing recovery unit.
RCLK RPOS RNEG RRING
In host mode, each channel can be setup as an independent G.703 timing recovery unit, through the Bits Clock Enable Register (1Eh) (See Section 14.31 on page 40), setting the desired bit to "1" enables BITS Clock mode for that channel. The following diagrams show how the BITS clock function operates.
RTIP
CS61880 One Receiver
0.1 F
R1
RECEIVE LINE
R2
T1 1:2
Figure 3. G.703 BITS Clock Mode in NRZ Mode
RCLK RPOS RNEG
RTIP
CS61880 One Receiver
0.1 F
R1
RECEIVE LINE
R2
RRING
T1 1:2
Figure 4. G.703 BITS Clock Mode in RZ Mode
RCLK RPOS RNEG
RTIP
CS61880 One Channel
0.1 F
R1
RECEIVE LINE
R2
RRING REMOTE LOOPBACK TCLK TPOS TNEG TRING TRANMIT LINE
T1 1:2
TTIP
T1 1:1.15
Figure 5. G.703 BITS Clock Mode in Remote Loopback
DS450PP3
23
CS61880
9. TRANSMITTER
The CS61880 contains eight identical transmitters that each use a low power matched impedance driver to eliminate the need for external load matching resistors, while providing superior return loss. As a result, the TTIP/TRING outputs can be connected directly to the transformer allowing one hardware circuit for E1 120 , and E1 75 applications. Digital transmit data and clock are input into the CS61880 through the TPOS/TDATA, TNEG and TCLK input pins. These pins accept data in one of three formats: unipolar, bipolar, or RZ. In either unipolar or bipolar mode, the CS61880 internally generates a pulse shape compliant to the G.703 mask for E1 (Refer to Figure 6). The pulse shaping applied to the transmit data can be selected in hardware mode or in host mode. In hardware mode, the line impedance (75 or 120 ) and which prestored pulse shape to transmit (75 or 120 ) is selected via the CBLSEL pin for all eight transmitters. In host mode, each channel is configured independently by writing to the Line Length Channel ID Register (10h) (See Section 14.17 on page 38), then writing the desired line length settings to the LEN[3:0] bits in the Line Length Data Register (11h) (See Section 14.18 on page 38). The LEN bits select the pulse shape and line impedance of the addressed channel. In host mode, the CBLSEL pin is not used.
NOTE: If one channel is configured for E1 75 mode, another channel can be configured for E1 120 mode at the same time. This operation is only allowed in host mode.
Percent of nominal peak voltage 120 110 244 ns 194 ns
269 ns
100
90 80
50
10 0 -10 -20 219 ns 488 ns
Nominal Pulse
Figure 6. Pulse Mask at E1 Interface
For more information on the host mode registers refer to Register Descriptions (See Section 14 on page 35).
9.1 Bipolar Mode
Bipolar mode provides transparent operation for applications in which the line coding function is performed by an external framing device. In this mode, the falling edge of TCLK samples NRZ data on TPOS/TNEG for transmission on TTIP/TRING.
The CS61880 also allows the user to customize the transmit pulse shapes to compensate for non-standard cables, transformers, or protection circuitry. For further information on the AWG Refer to Arbitrary Waveform Generator (See Section 15 on page 42).
9.2 Unipolar Mode
In unipolar mode, the CS61880 is configured such that transmit data is encoded using HDB3, or AMI line codes. This mode is activated by holding
24
DS450PP3
CS61880
TNEG/UBS "High" for more than 16 TCLK cycles. Transmit data is input to the part via the TPOS/TDATA pin on the falling edge of TCLK. When operating the part in hardware mode, the CODEN pin is used to select between HDB3 or AMI encoding. During host mode operation, the line coding is selected via the Line Length Channel ID Register (10h) (See Section 14.17 on page 38).
NOTE: The encoders/decoders are selected for all eight channels in both hardware and host mode.
In hardware mode, TAOS is activated by pulling TCLK "High" for more than 16 MCLK cycles. In host mode, TAOS is generated for a particular channel by asserting the associated bit in the TAOS Enable Register (03h) (See Section 14.4 on page 35). Since MCLK is the reference clock, it should be of adequate stability.
9.6 Automatic TAOS
While a given channel is in the LOS condition, if the corresponding bit in the Automatic TAOS Register (0Eh) (See Section 14.15 on page 37) is set, the device will drive that channel's TTIP and TRING with the all ones pattern. This function is only available in host mode. Refer to Loss-of-Signal (LOS) (See Section 10.5 on page 27).
9.3 RZ Mode
In RZ mode, the internal pulse shape circuitry is bypassed and RZ data driven into TPOS/TNEG is transmitted on TTIP/TRING. In this mode, the pulse width of the transmitter output is determined by the width of the RZ signal input to TPOS/TNEG pins. This mode is entered when MCLK is inactive and TCLK is held "High" for at least 12 s.
9.7 Driver Failure Monitor
In host mode, the Driver Failure Monitor (DFM) function monitors the output of each channel and sets a bit in the DFM Status Register (05h) (See Section 14.6 on page 35) if a secondary short circuit is detected between TTIP and TRING. This generates an interrupt if the respective bit in the DFM Interrupt Enable Register (07h) (See Section 14.8 on page 36) is also set. Any change in the DFM Status Register (05h) (See Section 14.6 on page 35) will result in the corresponding bit in the DFM Interrupt Status Register (09h) (See Section 14.10 on page 36) being set. The interrupt is cleared by reading the DFM Interrupt Status Register (09h) (See Section 14.10 on page 36).
9.4 Transmitter Powerdown / High-Z
The transmitters can be forced into a high impedance, low power state by holding TCLK of the appropriate channel low for at least 12 s or 140 MCLK cycles. In hardware and host mode, the TXOE pin forces all eight transmitters into a high impedance state within 1 s. In host mode, each transmitter is individually controllable using the Output Disable Register (12h) (See Section 14.19 on page 38). The TXOE pin can be used in host mode, but does not effect the contents of the Output Enable Register. This feature is useful in applications that require redundancy.
9.8 Driver Short Circuit Protection
The CS61880 provides driver short circuit protection when current on the secondary exceeds 50 mA RMS.
9.5 Transmit All Ones (TAOS)
When TAOS is activated, continuous ones are transmitted on TTIP/TRING using MCLK as the transmit timing reference. In this mode, the TPOS and TNEG inputs are ignored.
DS450PP3
25
CS61880
10. RECEIVER
The CS61880 contains eight identical receivers that utilize an internal matched impedance technique that provides for the use of a common set of external components for 120 (E1), and 75 (1) operation (Refer to Figure 16 on page 50). This feature enables the use of a one stuffing option for all E1 line impedances. The receivers can also be configured to use different external resistors to match the line impedance for E1 75 or E1 120 modes (Refer to Figure 17 on page 51). In hardware mode, the CBLSEL pin is used to select the proper line impedance (75 or 120 ) and either internal or external line impedance matching mode. In host mode, each receiver's line impedance is selected individually via the Line Length Channel ID Register (10h) (See Section 14.17 on page 38) and bits[3:0] and the LEN[3:0] bits of the Line Length Data Register (11h) (See Section 14.18 on page 38). The INT_EXTB bit of the Line Length Data Register (11h) (See Section 14.18 on page 38) is used to select between internal or external line impedance matching modes for all eight channels. The CBLSEL pin is not used in host mode. The CS61880 receiver provides all of the circuitry to recover both data and clock from the data signal input on RTIP and RRING. The matched impedance receiver is capable of recovering signals with 12 dB of attenuation (referenced to 2.37 V or 3.0 V nominal) while providing superior return loss. In addition, the timing recovery circuit along with the jitter attenuator provide jitter tolerance that far exceeds jitter specifications (Refer to Figure 19 on page 57). The recovered data and clock are output from the CS61880 on the RPOS/RDATA, RNEG and RCLK pins. These pins output the data in one of three formats: bipolar, unipolar, or RZ. The CLKE pin is used to configure RPOS/RDATA and RNEG, so that data is valid on either the rising or falling edge of RCLK. Refer to the CLKE pin description on page 13 for CLKE settings.
10.1 Bipolar Output Mode
Bipolar mode provides a transparent clock/data recovery for applications in which the line decoding is performed by an external framing device. The recovered clock and data are output on RCLK, RNEG and RPOS.
10.2 Unipolar Output Mode
In unipolar mode, the CS61880 decodes the recovered data with either HDB3 or AMI line decoding. The decoded data is output on the RPOS/RDATA pin. When bipolar violations are detected by the decoder, the RNEG/BPV pin is asserted "high". This pin is driven "high" for one RCLK period for every bipolar violation that is not part of the zero substitution rules. Unipolar mode is entered by holding the TNEG pin "high" for more than 16 TCLK cycles. In hardware mode, the HDB3/AMI encoding/decoding is activated via the CODEN pin. In host mode, Bit 4 of the Line Length Channel ID Register (10h) (See Section 14.17 on page 38) is used to select the encoding/decoding for all channels.
10.3 RZ Output Mode
In this mode the RTIP and RRING inputs are sliced to data values that are output on RPOS and RNEG pins. This mode is used in applications that have clock recovery circuitry external to the device. To support external clock recovery, the RPOS and RNEG outputs are XORed and output as RCLK. This mode is entered when MCLK is tied high. The polarity of the RPOS/RNEG data are controlled by the CLKE pin. Refer to the CLKE pin description on page 13 for CLKE settings.
26
DS450PP3
CS61880
10.4 Receiver Powerdown/High-Z
All eight receivers are powered down when MCLK is held low. In addition, this will force the RCLK, RPOS/RDATA and RNEG outputs into a high impedance state. tive zeros in a 32-bit sliding window and the signal level exceeds 250 mV. ETSI 300 233 (E1 Host Mode Only) - The LOS indicator becomes active when the receive signal level drops below 200 mV for more than 2048 pulse periods (1 ms). The channel exits the LOS state when the input signal exceeds 250 mV and has transitions for more than 32 pulse periods (16 s). This LOS detection method can only be selected while in host mode. During host mode operation, LOS is reported in the LOS Status Monitor Register. Both the LOS pins and the register bits reflect LOS status in host mode operation. The LOS pins and status bits are set high (indicating loss of signal) during reset, power-up, or channel powered-down.
10.5 Loss-of-Signal (LOS)
The CS61880 makes use of both analog and digital LOS detection circuitry that is compliant to the latest specifications. The LOS condition can be set to either ITU G.775 or ETSI 300 233. This change is done through the LOS/AIS Mode Enable Register (0Dh) (See Section 14.14 on page 37). The LOS detector increments a counter each time a zero is received, and resets the counter each time a one "mark" is received. Depending on LOS detection mode, the LOS signal is set when a certain number of consecutive zeros are received. In Clock/Data recovery mode, this forces the recovered clock to be replaced by MCLK at the RCLK output. In addition the RPOS/RDATA and RNEG outputs remain active for the length of the LOS period, except when local and analog loopbacks are enabled. Upon exiting LOS, the recovered clock replaces MCLK on the RCLK output. In Data recovery mode, RCLK is not replaced by MCLK when LOS is active. The LOS detection modes are summarized below.
NOTE: G.775 and ETSI 300 233 are both available in host mode, but in hardware mode only ETSI 300 233 is available.
10.6 Alarm Indication Signal (AIS)
The CS61880 detects all ones alarm condition per the relevant ITU, and ETSI specifications. In general, AIS is indicated when the one's density of the receive signal exceeds that dictated by the relevant specification. This feature is only available in host mode (Refer to LOS/AIS Mode Enable Register (0Dh) (See Section 14.14 on page 37)). ITU G.775 AIS (E1 Mode) - The AIS condition is declared when less than 3 zeros are received within two consecutive 512-bit windows. The AIS condition is cleared when 3 or more zeros are received in two consecutive 512-bit windows. ETSI 300 233 (E1 Mode) - The AIS condition is declared when less than 3 zeros are received in a 512-bit window. The AIS condition is cleared when a 512-bit window is received containing 3 or more zeros.
ITU G.775 (E1 Mode Only) - LOS is declared when the received signal level is less than 200 mV for 32 consecutive pulse periods (typical). The device exits LOS when the received signal achieves 12.5% ones density with no more than 15 consecu-
DS450PP3
27
CS61880
11. JITTER ATTENUATOR
The CS61880 internal jitter attenuators can be switched into either the receive or transmit paths. Alternatively, it can be removed from both paths to reduce the propagation delay. During Hardware mode operation, the location of the jitter attenuator for all eight channels are controlled by the JASEL pin (Refer to Table 7 for pin configurations). The jitter attenuator's FIFO length and corner frequency, can not be changed in hardware mode. The FIFO length and corner frequency are set to 32 bits and 1.25 Hz.
Table 7. Jitter Attenuator Configurations PIN STATE LOW HIGH OPEN JITTER ATTENUATOR POSITON Transmit Path Receive Path Disabled
(0Fh) also configures the jitter attenuator's FIFO length (bit 3) and corner frequency (bit 2). The attenuator consists of a 64-bit FIFO, a narrowband monolithic PLL, and control logic. The jitter attenuator requires no external crystal. Signal jitter is absorbed in the FIFO which is designed to neither overflow nor underflow. If overflow or underflow is imminent, the jitter transfer function is altered to ensure that no bit-errors occur. A configuration option is provided to reduce the jitter attenuator FIFO length from 64 bits to 32 bits in order to reduce propagation delay. The jitter attenuator -3 dB knee frequency depends on the settings of the Jitter Attenuator FIFO length and the Jitter Attenuator Corner Frequency, bits 2 and 3, in the Line Length Channel ID Register (10h) (See Section 14.17 on page 38)). Setting the lowest corner frequency guarantees jitter attenuation compliance to European specifications TBR 12/13 and ETS 300 011. The jitter attenuator is also compliant with ITU-T G.735, G.742, and G.783 (Refer to Figure 18 on page 56 and Figure 19 on page 57).
During host mode operation, the location of the jitter attenuator for all eight channels are set by bits 0 and 1 in the Line Length Channel ID Register (10h) (See Section 14.17 on page 38). This register
28
DS450PP3
CS61880
12. OPERATIONAL SUMMARY
A brief summary of the CS61880 operations in hardware and host mode is provided in Table 8.
Table 8. Operational Summary MCLK Active Active Active Active Active Active Active L L L H H H H H H H H H TCLK Active Active Active L H H H Active H L Active Active Active L L L H H H LOOP Open L H X Open L H X X X Open L H Open L H Open L H Receive Mode RCLK/Data Recovery RCLK/Data Recovery RCLK/Data Recovery RCLK/Data Recovery RCLK/Data Recovery RCLK/Data Recovery RCLK/Data Recovery Power Down Power Down Power Down Data Recovery Data Recovery Data Recovery Data Recovery Data Recovery Data Recovery Data Recovery Data Recovery Data Recovery Transmit Mode Unipolar/Bipolar Unipolar/Bipolar Unipolar/Bipolar Power Down TAOS Unipolar/Bipolar TAOS Unipolar/Bipolar RZ Data Power Down Unipolar/Bipolar RZ Data Unipolar/Bipolar Power Down RZ Data Power Down RZ Data RZ Data RZ Data Loopback Disabled Remote Loopback Analog Loopback Disabled Disabled Remote Loopback Analog Loopback Disabled Disabled Disabled Disabled Remote Loopback Analog Loopback Disabled Remote Loopback Disabled Disabled Remote Loopback Analog Loopback
12.1 Loopbacks
The CS61880 provides three loopback modes for each port. Analog Loopback connects the transmit signal on TTIP and TRING to RTIP and RRING. Digital Loopback Connects the output of the Encoder to the input of the Decoder (through the Jitter Attenuator if enabled). Remote Loopback connects the output of the Clock and Data Recovery block to the input of the Pulse Shaper block. (Refer to detailed descriptions below.) In hardware mode, the LOOP[7:0] pins are used to activate Analog or Remote loopback for each channel. In host mode, the Analog, Digital and Remote Loopback registers are used to enable these functions (Refer to the Analog Loopback Register (01h) (See Section 14.2 on page 35), Remote Loopback Register (02h) (See Section 14.3 on page 35), and Digital Loopback Reset Register (0Ch) (See Section 14.13 on page 36).
12.2 Analog Loopback
In Analog Loopback, the output of the TTIP/TRING driver is internally connected to the input of the RTIP/RRING receiver so that the data on TPOS/TNEG and TCLK appears on the RPOS/RNEG and RCLK outputs. In this mode the RTIP and RRING inputs are ignored. Refer to Figure 7 on page 30. In hardware mode, Analog Loopback is selected by driving LOOP[7:0] high. In host mode, Analog Loopback is selected for a given channel using the appropriate bit in the Analog Loopback Register (01h) (See Section 14.2 on page 35).
NOTE: The simultaneous selection of Analog and Remote loopback modes is not valid. A TAOS request overrides the data on TPOS and TNEG during Analog Loopback. Refer to Figure 8 on page 30.
DS450PP3
29
CS61880
Encoder
TPOS TNEG TCLK
Attenuator
Transmit Control & Pulse Shaper
Jitter
TTIP TRING
Decoder
RPOS RNEG RCLK
Attenuator
Jitter
Clock Recovery & Data Recovery
RTIP RRING
Figure 7. Analog Loopback Block Diagram
MCLK TAOS
Encoder
TPOS TNEG TCLK
Attenuator
Transmit Control & Pulse Shaper
Jitter
TTIP TRING (All One's)
Decoder
Jitter
RPOS RNEG RCLK
Attenuator
Clock Recovery & Data Recovery
RTIP RRING
Figure 8. Analog Loopback with TAOS Block Diagram
12.3 Digital Loopback
Digital Loopback causes the TCLK, TPOS, and TNEG (or TDATA) inputs to be looped back through the jitter attenuator (if enabled) to the RCLK, RPOS, and RNEG (or RDATA) outputs. The receive line interface is ignored, but data at TPOS and TNEG (or TDATA) continues to be transmitted to the line interface at TTIP and TRING (Refer to Figure 9 on page 31). Digital Loopback is only available during host mode. It is selected using the appropriate bit in the Digital Loopback Reset Register (0Ch) (See Section 14.13 on page 36).
NOTE: TAOS can also be used during the Digital Loopback operation for the selected channel (Refer to Figure 10 on page 31).
12.4 Remote Loopback
In remote loopback, the RPOS/RNEG and RCLK outputs are internally input to the transmit circuits for output on TTIP/TRING. In this mode the TCLK, TPOS and TNEG inputs are ignored. (Refer to Figure 11 on page 31). In hardware mode, Remote Loopback is selected by driving the LOOP pin for a certain channel low. In host mode, Remote Loopback is selected for a given channel by writing a one to the appropriate bit in the Remote Loopback Register (02h) (See Section 14.3 on page 35).
NOTE: In hardware mode, Remote Loopback overrides TAOS for the selected channel. In host mode, TAOS overrides Remote Loopback.
30
DS450PP3
CS61880
Encoder
TPOS TNEG TCLK
Jitter Attenuator
Transmit Control & Pulse Shaper
TTIP TRING
Decoder
RPOS RNEG RCLK
Jitter Attenuator
Clock Recovery & Data Recovery
RTIP RRING
Figure 9. Digital Loopback Block Diagram
MCLK TAOS Jitter Attenuator
Encoder
TPOS TNEG TCLK
Transmit Control & Pulse Shaper
TTIP TRING (All One's)
RPOS RNEG RCLK
Jitter Attenuator
Decoder
Clock Recovery & Data Recovery
RTIP RRING
Figure 10. Digital Loopback with TAOS
Encoder
TPOS TNEG TCLK
Jitter Attenuator
Transmit Control & Pulse Shaper
TTIP TRING
RPOS RNEG RCLK
Jitter Attenuator
Decoder
Clock Recovery & Data Recovery
RTIP RRING
Figure 11. Remote Loopback Block Diagram
DS450PP3
31
CS61880
13. HOST MODE
Host mode allows the CS61880 to be configured and monitored using an internal register set. (Refer to Table 1, "Operation Mode Selection," on page 10). The term, "Host mode" applies to both Parallel Host and Serial Host modes. All of the internal registers are available in both Serial and Parallel Host mode; the only difference is in the functions of the interface pins, which are described in Table 9 on page 32. Serial port operation is compatible with the serial ports of most microcontrollers. Parallel port operation can be configured to be compatible with 8-bit microcontrollers from Motorola or Intel, with both multiplexed or non-multiplexed address/data busses. (Refer to Table 10 on page 34 for host mode registers).
13.2 Serial Port Operation
Serial port host mode operation is selected when the MODE pin is left open or set to VCC/2. In this mode, the CS61880 register set is accessed by setting the chip select (CS) pin low and communicating over the SDI, SDO, and SCLK pins. Timing over the serial port is independent of the transmit and receive system timing. Figure 12 illustrates the format of serial port data transfers. A read or write is initiated by writing an address/command byte (ACB) to SDI. Only the ADR0-ADR4 bits are valid; bits ADR5-ADR6 are do not cares. During a read cycle, the register data addressed by the ACB is output on SDO on the next eight SCLK clock cycles. During a write cycle, the data byte immediately follows the ACB. Data is written to and read from the serial port in LSB first format. When writing to the port, SDI data is sampled by the device on the rising edge of SCLK. The valid clock edge of the data on SDO is controlled by the CLKE pin. When CLKE is low, data on SDO is valid on the falling edge of SCLK. When CLKE is high, data on SDO is valid on the raising edge of SCLK. The SDO pin is High-Z when not transmitting. If the host processor has a
13.1 SOFTWARE RESET
A software reset can be forced by writing the Software Reset Register (0Ah) (See Section 14.11 on page 36). A software reset initializes all registers to their default settings and initializes all internal state machines.
Table 9. Host Control Signal Descriptions HOST CONTROL SIGNAL DESCRIPTIONS PIN NAME MODE MUX CODEN/MOT/INTL ADDR [4] ADDR[3:0] LOOP[7:0], DATA[7:0] INT SDO/ACK/RDY SDI/DS/WR R/W/RD SCLK/AS/ALE JASEL/CS PIN # 11 43 88 12 13-16 28-21 82 83 84 85 86 87 HARDWARE LOW BITSEN0 CODEN GND ADDR[3:0] LOOP[7:0] Pulled Up NC GND GND GND JASEL SERIAL VDD/2 INT SDO SDI SCLK CS PARALLEL HIGH MUX MOT/INTL ADDR[4] ADDR [3:0] DATA[7:0] INT ACK/RDY DS/WR R/W/RD AS/ALE CS
32
DS450PP3
CS61880
bidirectional I/O port, SDI and SDO may be tied together. As illustrated in Figure 12, the ACB consists of a R/W bit, address field, and two reserved bits. The R/W bit specifies if the current register access is a read (R/W = 1) or a write (R/W = 0) operation. The address field specifies the register address from 0x00 to 0x1f. in Figure 28, Figure 26, Figure 25, Figure 27, Figure 29, Figure 30, Figure 31 and Figure 32. Multiplexed Intel and Motorola modes are shown in Figure 28, Figure 26, Figure 25 and Figure 27. A read or write is initiated by writing an address byte to D[7:0]. The device latches the address on the falling edge of ALE(AS). During a read cycle, the register data is output during the later portion of the RD or DS pulses. The read cycle is terminated and the bus returns to a high impedance state as RD transitions high in Intel timing or DS transitions high in Motorola timing. During a write cycle, valid write data must be present and held stable during the WR or DS pulses. Non-multiplexed Intel and Motorola modes are shown in Figure 29, Figure 30, Figure 32 and Figure 31. The CS pin initiates the cycle, followed by the DS, RD or WR pin. Data is latched into or out of the part using the rising edge of the DS, WR or RD pin. Raising CS ends the cycle. In Intel mode, the RDY output pin is normally in a high impedance state; it pulses low once to acknowledge that the chip has been selected, and high again to acknowledge that data has been written or read. In Motorola mode, the ACK pin performs a similar function; it drives high to indicate that the address has been received by the part, and goes low again to indicate that data has been written or read.
13.3 Parallel Port Operation
Parallel port host mode operation is selected when the MODE pin is high. In this mode, the CS61880 register set is accessed using an 8-bit, multiplexed bidirectional address/data bus D[7:0]. Timing over the parallel port is independent of the transmit and receive system timing. The device is compatible with both Intel and Motorola bus formats. The Intel bus format is selected when the INTL/MOT pin is high and the Motorola bus format is selected when the INTL/MOT pin is low. In either mode, the interface can have the address and data multiplexed over the same 8-bit bus or on separate busses. This operation is controlled with the MUX pin; MUX = 1 means that the parallel port has its address and data multiplexed over the same bus; MUX = 0 defines a non-multiplexed bus. The timing for the different modes are shown
CS
SCLK
SDI
R/W
0
0
0
0
1
0
0
D0
D1
D2
D3
D4
D5
D6
D7
Address/Command Byte
Data Input/Output
SDO CLKE=0
D0
D1
D2
D3
D4
D5
D6
D7
Figure 12. Serial Read/Write Format (SPOL = 0)
DS450PP3
33
CS61880
13.4 Register Set
The register set available during host mode operations are presented in Table 10. While the upper
REGISTERS
ADDR NAME Revision/IDCODE Analog Loopback Remote Loopback TAOS Enable LOS Status DFM Status LOS Interrupt Enable DFM Interrupt Enable LOS Interrupt Status DFM Interrupt Status Software Reset Performance Monitor Digital Loopback LOS/AIS Mode Enable Automatic TAOS Global Control Line Length Channel ID Line Length Data Output Disable AIS Status AIS Interrupt Enable AIS Interrupt Status AWG Broadcast AWG Phase Address AWG Phase Data AWG Enable RESERVED RESERVED RESERVED RESERVED BITS Clock Enable RESERVED TYPE R R/W R/W R/W R R R/W R/W R R R/W R/W R/W R/W R/W R/W R/W R/W R/W R R/W R R/W R/W R/W R R/W R R/W R/W ALBK 7 RLBK 7 7 6 ALBK 6 5 ALBK 5 4 ALBK 4
three bits of the parallel address are don't cares on the CS61880, they should be set to zero for proper operation.
Table 10. Host Mode Register Set BITS
3 2 1 ALBK 1 0 ALBK 0 IDCODE Refer to Device ID Register (IDR) on page 47 ALBK 3 ALBK 2 RLBK 6 RLBK 5 RLBK 4 RLBK 3 RLBK 2 RLBK 1 RLBK 0
00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 10h 11h 12h 13h 14h 15h 16h 17h 18h 19h 1Ah 1Bh 1Ch 1Dh 1Eh 1Fh
TAOE 7 TAOE 6 TAOE 5 TAOE 4 TAOE 3 TAOE 2 TAOE 1 TAOE 0 LOSS 7 LOSS 6 LOSS 5 LOSS 4 LOSS 3 LOSS 2 LOSS 1 LOSS 0 DFMS 7 DFMS 6 DFMS 5 DFMS 4 DFMS 3 DFMS 2 DFMS 1 DFMS 0 LOSE 7 LOSE 6 LOSE 5 LOSE 4 LOSE 3 LOSE 2 LOSE 1 LOSE 0 DFME 7 DFME 6 DFME 5 DFME 4 DFME 3 DFME 2 DFME 1 DFME 0 LOSI 7 DFMI 7 RSVD DLBK 7 ATAO 7 AI RSVD RSVD AISS 7 AISE 7 AISI 7 LOSI 6 DFMI 6 RSVD LOSI 5 DFMI 5 RSVD LOSI 4 DFMI 4 RSVD LOSI 3 DFMI 3 A3 LOSI 2 DFMI 2 A2 LOSI 1 DFMI 1 A1 LOSI 0 DFMI 0 A0
SRES 7 SRES 6 SRES 5 SRES 4 SRES 3 SRES 2 SRES 1 SRES 0 DLBK 6 DLBK 5 ATAO 6 Raisen RSVD RSVD AISS 6 AISE 6 AISI 6 ATAO 5 RSVD RSVD RSVD AISS 5 AISE 5 AISI 5 DLBK 4 DLBK 3 DLBK 2 DLBK 1 DLBK 0 ATAO 4 ATAO 3 ATAO 2 ATAO 1 ATAO 0 Coden RSVD IN_EX AISS 4 AISE 4 AISI 4 AISS 3 AISE 3 AISI 3 FIFO RSVD JACF JASEL [1:0] Channel ID LEN[3:0] AISS 2 AISE 2 AISI 2 AISS 1 AISE 1 AISI 1 AISS 0 AISE 0 AISI 0
LAME 7 LAME 6 LAME 5 LAME 4 LAME 3 LAME 2 LAME 1 LAME 0
OENB 7 OENB 6 OENB 5 OENB 4 OENB 3 OENB 2 OENB 1 OENB 0
R/W AWGB 7 AWGB 6 AWGB 5 AWGB 4 AWGB 3 AWGB 2 AWGB 1 AWGB 0 Channel Address [2:0] RSVD Phase Address [4:0] Sample Data[6:0]
R/W AWGN 7 AWGN 6 AWGN 5 AWGN 4 AWGN 3 AWGN 2 AWGN 1 AWGN 0 RSVD 7 RSVD 6 RSVD 5 RSVD 4 RSVD 3 RSVD 2 RSVD 1 RSVD 0 RSVD 7 RSVD 6 RSVD 5 RSVD 4 RSVD 3 RSVD 2 RSVD 1 RSVD 0 RSVD 7 RSVD 6 RSVD 5 RSVD 4 RSVD 3 RSVD 2 RSVD 1 RSVD 0 RSVD 7 RSVD 6 RSVD 5 RSVD 4 RSVD 3 RSVD 2 RSVD 1 RSVD 0 BITS 7 BITS 6 BITS 5 BITS 4 BITS 3 BITS 2 BITS 1 BITS 0 RSVD 7 RSVD 6 RSVD 5 RSVD 4 RSVD 3 RSVD 2 RSVD 1 RSVD 0
34
DS450PP3
CS61880
14. REGISTER DESCRIPTIONS 14.1 Revision/IDcode Register (00h)
BIT [7:4] NAME REVI 7-4 Description Bits [7:4] are taken from the least-significant nibble of the Device IDCode, which are 0000. (Refer to Device ID Register (IDR) (See Section 16.3 on page 47). Bits [3:0] are the revision bits from the JTAG IDCODE register, CS61880 Revision A = 0000. These bits are subject to change with the revision of the device (Refer to Device ID Register (IDR) (See Section 16.3 on page 47).
[3:0]
REVI 3-0
14.2 Analog Loopback Register (01h)
BIT [7:0] NAME ALBK 7-0 Description Enables analog loopbacks. A "1" in bit n enables the loopback for channel n. Refer to Analog Loopback (See Section 12.2 on page 29) for a complete explanation. Register bits default to 00h after power-up or reset.
14.3 Remote Loopback Register (02h)
BIT [7:0] Description Enables remote loopbacks. A "1" in bit n enables the loopback for channel n. Refer to HOST RLBK 7-0 MODE (See Section 13 on page 32) for a complete explanation. Register bits default to 00h after power-up or reset. NAME
14.4 TAOS Enable Register (03h)
BIT [7:0] NAME Description TAOE 7-0 A "1" in bit n of this register turns on the TAOS generator in channel n. Register bits default to 00h after power-up or reset.
14.5 LOS Status Register (04h)
BIT [7:0] NAME Description LOSS 7-0 Register bit n is read as "1" when LOS is detected on channel n. Register bits default to 00h after power-up or reset.
14.6 DFM Status Register (05h)
BIT [7:0] NAME Description DFMS 7-0 Driver Failure Monitor. The DFM will set bit n to "1" when it detects a short circuit in channel n. Register bits default to 00h after power-up or reset.
DS450PP3
35
CS61880
14.7 LOS Interrupt Enable Register (06h)
BIT [7:0] NAME Description LOSE 7-0 Any change in a LOS Status Register will cause the INT pin to go low if corresponding bit in this register is set to "1". Register bits default to 00h after power-up or reset.
14.8 DFM Interrupt Enable Register (07h)
BIT [7:0] Description Enables interrupts for failures detected by the DFM. Any change in a DFM Status Register bit DFME 7-0 will cause an interrupt if the corresponding bit is set to "1" in this register. Register bits default to 00h after power-up or reset. NAME
14.9 LOS Interrupt Status Register (08h)
BIT [7:0] NAME LOSI 7-0 Description Bit n of this register is set to "1" to indicate a status change in bit n of the LOS Status Register. The bits in this register indicate a change in status since the last cleared LOS interrupt. Register bits default to 00h after power-up or reset.
14.10 DFM Interrupt Status Register (09h)
BIT [7:0] NAME DFMI 7-0 Description Bit n of this register is set to "1" to indicate a status change in bit n of the DFM Status Register. The bits in this register indicate a change in status since the last cleared DFM interrupt. Register bits default to 00h after power-up or reset.
14.11 Software Reset Register (0Ah)
BIT [7:0] NAME Description SRES 7-0 Writing to this register initializes all registers to their default settings. Register bits default to 00h after power-up or reset.
14.12 Performance Monitor Register (0Bh)
BIT [7:4] [3:0] NAME Description RSVD 7-4 RESERVED (These bits must be set to 0.) A[3:0] The G.772 Monitor is directed to a given channel based on the state of the four least significant bits of this register. Register bits default to 00h after power-up or reset. The following table shows the settings needed to select a specific channel's receiver or transmitter to perform G.772 monitoring. See Table 6 on page 22 for G.772 Monitor Settings.
14.13 Digital Loopback Reset Register (0Ch)
BIT [7:0] NAME Description DLBK 7-0 Setting register bit n to "1" enables the digital loopback for channel n. Refer to Digital Loopback (See Section 12.3 on page 30) for a complete explanation. Register bits default to 00h after power-up or reset.
36
DS450PP3
CS61880
14.14 LOS/AIS Mode Enable Register (0Dh)
BIT [7:0] NAME Description LAME 7-0 Setting bit n to "1" enables ETSI 300 233 compliant LOS/AIS for channel n; setting bit n to "0" enables ITU G.775 compliant LOS/AIS for channel n. Register bits default to 00h after power-up or reset.
14.15 Automatic TAOS Register (0Eh)
BIT [7:0] NAME Description ATAO 7-0 Setting bit n to "1" enables automatic TAOS generation on channel n when LOS is detected. Register bits default to 00h after power-up or reset.
14.16 Global Control Register (0Fh)
BIT Description This register is the global control for the AWG Auto-Increment, Automatic AIS insertion, encoding/decoding and the jitter attenuators location, FIFO length and corner frequency for all eight channels. Register bits default to 00h after power-up or reset. The AWG Auto-Increment bit indicates whether to auto-increment the AWG Phase Address AWG Auto- Register (17h) (See Section 14.24 on page 39) after each access. Thus, when this bit is set, Increment the phase samples address portion of the address register increments after each read or write access. This bit must be set before any bit in the AWG Enable register is set, if this function is required. On LOS, this bit controls the automatic AIS insertion into all eight receiver paths. RAISEN 0 = Disabled 1 = Enabled RSVD RESERVED (This bit must be set to 0.) Line encoding/decoding Selection 0 = HDB3 CODEN 1 = AMI Jitter Attenuator FIFO length Selection FIFO 0 = 32 bits LENGTH 1 = 64 bits Jitter Attenuator Corner Frequency Selection 0 = 1.25 Hz JACF 1 = 2.50 Hz These bits select the position of the Jitter Attenuator. Table 11. Jitter Attenuator Position Selection [1:0] JASEL [1:0] JASEL 1 0 0 1 1 JASEL 0 0 1 0 1 POSITION Disabled Transmit Path Disabled Receive Path NAME
[7]
[6] [5] [4]
[3]
[2]
DS450PP3
37
CS61880
14.17 Line Length Channel ID Register (10h)
BIT [7:3] NAME RSVD 7-3 Description RESERVED (These bits must be set to 0.) The value written to these bits specify the LIU channel for which the Pulse Shape Configuration Data (register 11h) applies. For example, writing a value of a binary 000 to the 3-LSBs will select channel 0. The pulse shape configuration data for the channel specified in this register are written or read through the Line Length Data Register (11h). Register bits default to 00h after power-up or reset.
[2:0]
LLID 2-0
14.18 Line Length Data Register (11h)
BIT Description The value written to the 4-LSBs of this register specifies whether the device is operating in either E1 75 or E1 120 mode and the associated pulse shape as shown below is being transmitted. Register bits default to 00h after power-up or reset. RSVD RESERVED (These bits must be set to 0.) This bit specifies the use of internal (Int_ExtB = 1) or external (Int_ExtB = 0) receiver line INT_EXTB matching. The line impedance for both the receiver and transmitter are chosen through the LEN [3:0] bits in this register. These bits set the line impedance for both the receiver and the transmitter path and the LEN[3:0] desired pulse shape for a specific channel. The channel is selected with the Line Length Channel ID register (0x10). The following table shows the available transmitter pulse shapes. Table 12. Transmitter Pulse Shape Selection LEN [3:0] 0000 1000 Operation Mode E1 E1 Line Length Selection 120 3.0 V 75 2.37 V Phase Samples per UI 12 12 NAME
[7:5] [4]
[3:0]
14.19 Output Disable Register (12h)
BIT [7:0] NAME Description OENB 7-0 Setting bit n of this register to "1" High-Z the TX output driver on channel n of the device. Register bits default to 00h after power-up or reset.
14.20 AIS Status Register (13h)
BIT [7:0] NAME AISS 7-0 Description A "1" in bit position n indicates that the receiver has detected an AIS condition on channel n, which generates an interrupt on the INT pin. Register bits default to 00h after power-up or reset.
38
DS450PP3
CS61880
14.21 AIS Interrupt Enable Register (14h)
BIT [7:0] NAME AISE 7-0 Description This register enables changes in the AIS Status register to be reflected in the AIS Interrupt Status register, thus causing an interrupt on the INT pin. Register bits default to 00h after power-up or reset.
14.22 AIS Interrupt Status Register (15h)
BIT [7:0] NAME AISI 7-0 Description Bit n is set to "1" to indicate a change of status of bit n in the AIS Status Register. The bits in this register indicate which channel changed in status since the last cleared AIS interrupt. Register bits default to 00h after power-up or reset.
14.23 AWG Broadcast Register (16h)
BIT [7:0] Description Setting bit n to "1" causes the phase data in the AWG Phase Data Register to be written to AWGB 7-0 the corresponding channel or channels simultaneously. (Refer to Arbitrary Waveform Generator (See Section 15 on page 42). Register bits default to 00h after power-up or reset. NAME
14.24 AWG Phase Address Register (17h)
BIT [7:5] [4:0] NAME AWGA PA[4:0] Description These bits specify the target channel 0-7. (Refer to Arbitrary Waveform Generator (See Section 15 on page 42). Register bits default to 00h after power-up or reset. These bits specify 1 of 24 phase sample address locations of the AWG, that the phase data in the AWG Phase Data Register is written to or read from. Register bits default to 00h after power-up or reset.
14.25 AWG Phase Data Register (18h)
BIT [7] Description RESERVED (This bit must be set to 0.) These bits are used for the pulse shape data that will be written to or read from the AWG phase location specified by the AWG Phase Address Register. The value written to or read from this register will be written to or read from the AWG phase sample location specified by AWGD [6:0] the AWG Phase Address register. A software reset through the Software Reset Register does not effect the contents of this register. The data in each phase is a 7-bit 2's complement number (the maximum positive value is 3Fh and the maximum negative value is 40h). (Refer to Arbitrary Waveform Generator (See Section 15 on page 42). Register bits default to 00h after power-up. NAME RSVD
[6:0]
DS450PP3
39
CS61880
14.26 AWG Enable Register (19h)
BIT Description The AWG enable register is used for selecting the source of the customized transmission pulse-shape. Setting bit n to "1" in this register selects the AWG as the source of the output AWGN 7-0 pulse shape for channel n. When bit n is set to "0" the pre-programmed pulse shape in the ROM is selected for transmission on channel n. (Refer to Arbitrary Waveform Generator (See Section 15 on page 42). Register bits default to 00h after power-up or reset. NAME
[7:0]
14.27 Reserved Register (1Ah)
BIT [7:0] NAME RSVD 7-0 Description RESERVED
14.28 Reserved Register (1Bh)
BIT [7:0] NAME RSVD 7-0 Description RESERVED
14.29 Reserved Register (1Ch)
BIT [7:0] NAME RSVD 7-0 Description RESERVED
14.30 Reserved Register (1Dh)
BIT [7:0] NAME RSVD 7-0 Description RESERVED
14.31 Bits Clock Enable Register (1Eh)
BIT [7:0] NAME BITS 7-0 Description Writing a "1" to bit n in this register changes channel n to a stand-alone timing recovery unit used for G.703 clock recovery. (Refer to BUILDING INTEGRATED TIMING SYSTEMS (BITS) CLOCK MODE (See Section 8 on page 23) for a better description of the G.703 clock recovery function). Register bits default to 00h after power-up or reset.
14.32 Reserved Register (1Fh)
BIT [7:0] NAME RSVD 7-0 Description RESERVED
14.33 Status Registers
The following Status registers are read-only: LOS Status Register (04h) (See Section 14.5 on page 35), DFM Status Register (05h) (See Sec40
tion 14.6 on page 35) and AIS Status Register (13h) (See Section 14.20 on page 38). The CS61880 generates an interrupt on the INT pin any time an unmasked status register bit changes.
DS450PP3
CS61880
14.33.1 Interrupt Enable Registers
The Interrupt Enable registers: LOS Interrupt Enable Register (06h) (See Section 14.7 on page 36), DFM Interrupt Enable Register (07h) (See Section 14.8 on page 36), AIS Interrupt Enable Register (14h) (See Section 14.21 on page 39), enable changes in status register state to cause an interrupt on the INT pin. Interrupts are maskable on a per channel basis. When an Interrupt Enable register bit is 0, the corresponding Status register bit is disabled from causing an interrupt on the INT pin.
NOTE: Disabling an interrupt has no effect on the status reflected in the associated status register.
14.33.2 Interrupt Status Registers
The following interrupt status registers: LOS Interrupt Status Register (08h) (See Section 14.9 on page 36), DFM Interrupt Status Register (09h) (See Section 14.10 on page 36), AIS Interrupt Status Register (15h) (See Section 14.22 on page 39), indicate a change in status of the corresponding status registers in host mode. Reading these registers clears the interrupt, which deactivates the INT pin.
DS450PP3
41
CS61880
15. ARBITRARY WAVEFORM GENERATOR
Using the Arbitrary Waveform Generator (AWG) allows the user to customize the transmit pulse shapes to compensate for nonstandard cables, transformers, protection circuitry, or to reduce power consumption by reducing the output pulse amplitude. A channel is configured for a custom pulse shape by enabling the AWG for that channel and then storing data representing the pulse shape into the 24 phase sample locations. Each channel has a separate AWG, so all eight channels can have a different customized pulse shape. The microprocessor interface, is used to read from or write to the AWG, while the device is in host mode. In the AWG RAM, the pulse shape is divided into two unit intervals (UI). There are 12 phase sample addresses in each UI. The first UI is for the main part of the pulse and the second UI is for the "tail" of the pulse (Refer to Figure 13). A complete pulseshape is represented by 24 phase samples. Data written in the first UI represents a valid pulse shape, while data in the second UI must be set to zero at all times. Writing values other that zero to the second UI will cause the pulse shape to be invalid. The data in each phase sample is a 7-bit two's complement number with a maximum positive value of 0x3f, and a maximum negative value of 0x40. The terms "positive" and "negative" are defined for a positive going pulse only. The pulse generation circuitry automatically inverts the pulse for negative going pulses. The data stored in the lowest phase address corresponds to the first phase sample that will be transmitted in time. The typical voltage step for each mode of operation is as follows: for E1 75 mode the typical voltage step is 42 mV/LSB and for E1 120 mode the typical voltage step is 54 mV/LSB all voltage steps are measured across the transformer secondary. The following procedure describes how to enable and write data into the AWG RAM to produce customized pulse shapes to be transmitted for a specific channel or channels. First, enable the AWG function for a specific channel or channels by writing a "1" to the corresponding bits in the AWG Enable Register (19h) (See Section 14.26 on page 40). When the corresponding bit or bits in the AWG Enable Register are set to "0" pre-programmed pulse shapes are selected for transmission. Then the desired channel and phase sample address must be written to the AWG Phase Address Register (17h) (See Section 14.24 on page 39). Once the channel and phase sample address have been written, the actual phase sample data may be entered into the AWG Phase Data Register (18h) (See Section 14.25 on page 39) at the selected phase sample address selected by the lower five bits of the AWG Phase Address Register (17h) (See Section 14.24 on page 39)). To change the phase sample address of the selected channel the user may use either of the following steps. The user can re-write the phase sample address to the AWG Phase Address Register or set the Auto-Increment bit (Bit 7) in the Global Control Register (0Fh) (See Section 14.16 on page 37) to "1" before writing to the AWG Phase Data Register. When this bit is set to "1" only the first phase
DS450PP3
U1
U2
E1 AWG Example
Figure 13. Arbitrary Waveform UI
42
CS61880
sample address (00000 binary) needs to be written to the AWG Phase Address Register (17h) (See Section 14.24 on page 39), and each subsequent access (read or write) to the AWG Phase Data Register (18h) (See Section 14.25 on page 39) will automatically increment the phase sample address. The channel address, however, remains unaffected by the Auto-Increment mode. The AWG Phase Address Register (17h) (See Section 14.24 on page 39) needs to be re-written in order to re-start the phase sample address sequence from the new phase sample address. The AWG Broadcast function allows the same data to be written to multiple channels simultaneously. This is done with the use of the AWG Broadcast Register (16h) (See Section 14.23 on page 39), each bit in the AWG Broadcast Register corresponds to a different channel (e.g. bit 0 is channel 0, and bit 3 is channel 3 and etc.). To use the AWG Broadcast function MCLK must be present. When MCLK is inactive the AWG Broadcast function is disabled. To write the same pulse shaping data to multiple channels, simple set the corresponding bit to "1" in the AWG Broadcast Register (16h) (See Section 14.23 on page 39) before accessing the AWG phase data register. This function only requires that one of the eight channel addresses be written to the AWG Phase Address Register (17h) (See Section 14.24 on page 39). During an AWG read sequence, the bits in the AWG Broadcast Register are ignored. During an AWG write sequence, the selected channel or channels are specified by both the channel address specified by the upper bits of the AWG Phase Address Register (17h) (See Section 14.24 on page 39) and the selected channel or channels in the AWG Broadcast Register (16h) (See Section 14.23 on page 39). During a multiple channel write the first channel that is written to, is the channel that was addressed by the AWG Phase Address Register. This channel's bit in the AWG Broadcast Register can be set to either "1" or "0". For a more descriptive explanation of how to use the AWG function refer to the Application Note AN204, How To Use The CS61880/CS61884 Arbitrary Waveform Generator.
16. JTAG SUPPORT
The CS61880 supports the IEEE Boundary Scan Specification as described in the IEEE 1149.1 standards. A Test Access Port (TAP) is provided that consists of the TAP controller, the instruction register (IR), by-pass register (BPR), device ID register (IDR), the boundary scan register (BSR), and the 5 standard pins (TRST, TCK, TMS, TDI, and TDO). A block diagram of the test access port is shown in Figure 14 on page 44. The test clock input (TCK) is used to sample input data on TDI, and shift output data through TDO. The TMS input is used to step the TAP controller through its various states. The instruction register is used to select test execution or register access. The by-pass register provides a direct connection between the TDI input and the TDO output. The device identification register contains a 32-bit device identifier. The Boundary Scan Register is used to support testing of IC inter-connectivity. Using the Boundary Scan Register, the digital input pins can be sampled and shifted out on TDO. In addition, this register can also be used to drive digital output pins to a user defined state.
DS450PP3
43
CS61880
Digital output pins Digital input pins parallel latched output Boundary Scan Data Register TDI Device ID Data Register MUX Bypass Data Register TCK Instruction (shift) Register parallel latched output TAP Controller TDO JTAG BLOCK
TMS
Figure 14. Test Access Port Architecture
16.1 TAP Controller
The TAP Controller is a 16 state synchronous state machine clocked by the rising edge of TCK. The TMS input governs state transitions as shown in Figure 15. The value shown next to each state transition in the diagram is the value that must be on TMS when it is sampled by the rising edge of TCK.
16.1.4 Select-DR-Scan
This is a temporary controller state.
16.1.5 Capture-DR
In this state, the Boundary Scan Register captures input pin data if the current instruction is EXTEST or SAMPLE/PRELOAD.
16.1.1 JTAG Reset
TRST resets all JTAG circuitry.
16.1.6 Shift-DR
In this controller state, the active test data register connected between TDI and TDO, as determined by the current instruction, shifts data out on TDO on each rising edge of TCK.
16.1.2 Test-Logic-Reset
The test-logic-reset state is used to disable the test logic when the part is in normal mode of operation. This state is entered by asynchronously asserting TRST or forcing TMS High for 5 TCK periods.
16.1.7 Exit1-DR
This is a temporary state. The test data register selected by the current instruction retains its previous value.
16.1.3 Run-Test-Idle
The run-test-idle state is used to run tests.
44
DS450PP3
CS61880
1
Test-Logic-Reset 0 1 1 1
0
Run-Test/Idle
Select-DR-Scan 0 1 Capture-DR 0 Shift-DR 1 Exit1-DR 0 Pause-DR 1 0 Exit2-DR 1 Update-DR 1 0
Select- I R-Scan 0 1 Capture- IR 0 0 Shift- IR 1
0 1
1
Exit1- IR 0 0 0 Pause- IR 1 Exit2- IR 1 Update- IR 1 0
0
Figure 15. TAP Controller State Diagram
16.1.8 Pause-DR
The pause state allows the test controller to temporarily halt the shifting of data through the current test data register.
on the falling edge of TCK. The data held at the latched parallel output changes only in this state.
16.1.11 Select-IR-Scan
This is a temporary controller state. The test data register selected by the current instruction retains its previous state.
16.1.9 Exit2-DR
This is a temporary state. The test data register selected by the current instruction retains its previous value.
16.1.12 Capture-IR
In this controller state, the instruction register is loaded with a fixed value of "01" on the rising edge of TCK. This supports fault-isolation of the boardlevel serial test data path.
16.1.10 Update-DR
The Boundary Scan Register is provided with a latched parallel output to prevent changes while data is shifted in response to the EXTEST and SAMPLE/PRELOAD instructions. When the TAP controller is in this state and the Boundary Scan Register is selected, data is latched into the parallel output of this register from the shift-register path
16.1.13 Shift-IR
In this state, the shift register contained in the instruction register is connected between TDI and TDO and shifts data one stage towards its serial output on each rising edge of TCK.
DS450PP3
45
CS61880
16.1.14 Exit1-IR
This is a temporary state. The test data register selected by the current instruction retains its previous value.
Table 13. JTAG Instructions IR CODE 000 100 110 111 INSTRUCTION EXTEST SAMPLE/PRELOAD IDCODE BYPASS
16.1.15 Pause-IR
The pause state allows the test controller to temporarily halt the shifting of data through the instruction register.
16.2.1 EXTEST
The EXTEST instruction allows testing of off-chip circuitry and board-level interconnect. EXTEST connects the BSR to the TDI and TDO pins.
16.1.16 Exit2-IR
This is a temporary state. The test data register selected by the current instruction retains its previous value.
16.2.2 SAMPLE/PRELOAD
The SAMPLE/PRELOAD instruction samples all device inputs and outputs. This instruction places the BSR between the TDI and TDO pins. The BSR is loaded with samples of the I/O pins by the Capture-DR state.
16.1.17 Update-IR
The instruction shifted into the instruction register is latched into the parallel output from the shift-register path on the falling edge of TCK. When the new instruction has been latched, it becomes the current instruction. The test data registers selected by the current instruction retain their previous value.
16.2.3 IDCODE
The IDCODE instruction connects the device identification register to the TDO pin. The device identification code can then be shifted out TDO using the Shift-DR state.
16.2 Instruction Register (IR)
The 3-bit Instruction register selects the test to be performed and/or the data register to be accessed. The valid instructions are shifted in LSB first and are listed in Table 13:
16.2.4 BYPASS
The BYPASS instruction connects a one TCK delay register between TDI and TDO. The instruction is used to bypass the device.
46
DS450PP3
CS61880
16.3 Device ID Register (IDR)
Revision section: 0h = Rev A, 1h = Rev B and so on. The device Identification Code [27 - 12] is derived from the last three digits of the part number (880). The LSB is a constant 1, as defined by IEEE 1149.1. CS61880 IDCODE REGISTER(IDR)
REVISION 0h 0 0 0 0 0 0h 0 0 0 1 DEVICE IDCODE REGISTER 8h 0 0 0 1 8h 0 0 0 0 0h 0 0 0 0 MANUFACTURER CODE 8 0 7 1 6 1 5 0 4 0 3 1 2 0 1 0 0 1 0h 0 0 Ch 9h 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
17. BOUNDARY SCAN REGISTER (BSR)
The BSR is a shift register that provides access to the digital I/O pins. The BSR is used to read and write the device pins to verify interchip connectivity. Each pin has a corresponding scan cell in the register. The pin to scan cell mapping is given in the Boundary Scan Register description shown in Table 14.
NOTE: Data is shifted LSB first into the BSR register. Table 14. Boundary Scan Register BSR Bit
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
Pin Name
LOS7 RNEG7 RPOS7 RCLK7 TNEG7 TPOS7 TCLK7 LOS6 RNEG6 RPOS6 RCLK6 TNEG6 TPOS6 TCLK6 MCLK MODE MODE ADDR4 ADDR3 ADDR2 ADDR1 ADDR0 LOOP0/D0 LOOP0/D0 LOOP0/D0 LOOP1/D1
Cell Type
O O O O Note 2 I I I O O O O Note 2 I I I I I I I I I I I I I O I
Bit Symbol
LOS7 RNEG7 RPOS7 RCLK7 HIZ7_B TNEG7 TPOS7 TCLK7 LOS6_B RNEG6 RPOS6 RCLK6 HIZ6_B TNEG6 TPOS6 TCLK6 MCLK MODE_TRI MODE_IN ADDR4 ADDR3 ADDR2 ADDR1 ADDR0 LPT0 LPI0 LPO0 LPT1
DS450PP3
47
CS61880
Table 14. Boundary Scan Register (Continued) BSR Bit
28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72
Pin Name
LOOP1/D1 LOOP1/D1 LOOP2/D2 LOOP2/D2 LOOP2/D2 LOOP3/D3 LOOP3/D3 LOOP3/D3 LOOP4/D4 LOOP4/D4 LOOP4/D4 LOOP5/D5 LOOP5/D5 LOOP5/D5 LOOP6/D6 LOOP6/D6 LOOP6/D6 LOOP7/D7 LOOP7/D7 LOOP7/D7 TCLK1 TPOS1 TNEG1 RCLK1 RPOS1 RNEG1 LOS1 TCLK0 TPOS0 TNEG0 RCLK0 RPOS0 RNEG0 LOS0 MUX LOS3 RNEG3 RPOS3 RCLK3 TNEG3 TPOS3
Cell Type
I O I I O I I O I I O I I O I I O I I O Note I I I O O O Note O I I I O O O Note O I O O O O Note I I
Bit Symbol
LPI1 LPO1 LPT2 LPI2 LPO2 LPT3 LPI3 LPO3 LPT4 LPI4 LPO4 LPT5 LPI5 LPO5 LPT6 LPI6 LPO6 LPT7 LPI7 LPO7 LPOEN TCLK1 TPOS1 TNEG1 RCLK1 RPOS1 RNEG1 HIZ1_B LOS1 TCLK0 TPOS0 TNEG0 RCLK0 RPOS0 RNEG0 HIZ0_B LOS0 MUX LOS3 RNEG3 RPOS3 RCLK3 HIZ3_B TNEG3 TPOS3
1
2
2
2
48
DS450PP3
CS61880
Table 14. Boundary Scan Register (Continued) BSR Bit
73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 Notes: 1)
Pin Name
TCLK3 LOS2 RNEG2 RPOS2 RCLK2 TNEG2 TPOS2 TCLK2 INT_B RDY WR_B RD_B ALE CS_B CS_B INTL CBLSEL CBLSEL TCLK5 TPOS5 TNEG5 RCLK5 RPOS5 RNEG5 LOS5 TCLK4 TPOS4 TNEG4 RCLK4 RPOS4 RNEG4 LOS4 TXOE CLKE
Cell Type
I O O O O Note I I I O O Note I I I I I I I I I I I O O O Note O I I I O O O Note O I I
Bit Symbol
TCLK3 LOS2 RNEG2 RPOS2 RCLK2 HIZ2_B TNEG2 TPOS2 TCLK2 INT_B RDYOUT RDYOEN WR_B RD_B ALE CS_B CS_B_TRI INTL CBLSEL_TRI CBLSEL_IN TCLK5 TPOS5 TNEG5 RCLK5 RPOS5 RNEG5 HIZ5_B LOS5 TCLK4 TPOS4 TNEG4 RCLK4 RPOS4 RNEG4 HIZ4_B LOS4 TXOE CLKE
2
3
2
2
2) 3)
LPOEN controls the LOOP[7:0] pins. Setting LPOEN to "1" configures LOOP[7:0] as outputs. The output value driven on the pins are determined by the values written to LPO[7:0]. Setting LPOEN to "0" High-Z all the pins. In this mode, the input values driven to these LOOP[7:0] can be read via LPI[7:0]. HIZ_B controls the RPOSx, RNEGx, and RCLKx pins. When HIZ_B is High, the outputs are enabled; when HIZ_B is Low, the outputs are placed in a high impedance state (High-Z). RDYOEN controls the ACK_B pin. Setting RDYOEN to "1" enables output on ACK_B. Setting ACKEN to "0" High -Z the ACK_B pin.
DS450PP3
49
CS61880
18. APPLICATIONS
+3.3V 0.1 F
Note 1 RGND RV+ TV+ R TIP
0.1 F
Note 1
+
+
68 F
Note 2
TGND
+3.3V
VCCIO
0.1 F
R1 RECEIVE LINE R2
0.1 F
GNDIO
+
R RIN G
T1 1:2 CS61880 One Channel
T RIN G TRANSMIT LINE T TIP
75 Cable
NC
+3.3V
T2 1:1.15 13.3k
CBLSEL REF
120 Cable
GND
Component R1 () R2 ()
E1 75 Coaxial Cable 15 15
E1 120 Twisted Pair Cable 15 15
Notes:1) Required Capacitor between each TV+, RV+, VCCIO and TGND, RGND, GNDIO respectively. 2) Common decoupling capacitor for all TVCC and TGND pins.
Figure 16. Internal RX/TX Impedance Matching
50
DS450PP3
CS61880
+3.3V 0.1 F
Note 1 RGND RV+ TV+ R TIP
0.1 F
Note 1
+
+
68 F
Note 2
TGND
1k 0.1 F
R1
+3.3V
VCCIO
RECEIVE LINE
R2
0.1 F
GNDIO
+
R RIN G
1k CS61880 One Channel
T RIN G T TIP
T1 1:2
TRANSMIT LINE
120 Cable
T2 1:1.15
CBLSEL REF
NC
75 Cable
13.3k
GND
GND
Component R1 () R2 () Notes:
E1 75 Coaxial Cable 9.31 9.31
E1 120 Twisted Pair Cable 15 15
1)Required Capacitor between each TV+, RV+, VCCIO and TGND, RGND, GNDIO respectively. 2)Common decoupling capacitor for all TVCC and TGND pins.
Figure 17. Internal TX, External RX Impedance Matching
DS450PP3
51
CS61880
18.1 Transformer Specifications
Recommended transformer specifications are shown in Table 15. Any transformer used with the CS61880 should meet or exceed these specifications.
Table 15. Transformer Specifications Descriptions Turns Ratio Receive Turns Ratio Transmit Primary Inductance Primary Leakage Inductance Secondary leakage Inductance Inter winding Capacitance ET-Constant Specifications 1:2 1:1.15 1.5 mH min @ 1024 kHz 0.3 H max @ 1024 kHz 0.4 H max @ 1024 kHz 18 pF max, primary to secondary 16 V - s min
18.2 Crystal Oscillator Specifications
When a reference clock signal is not available, a CMOS crystal oscillator may be used as the reference clock signal. The oscillator must have a minimum symmetry of 40-60% and minimum stability of + 100 ppm.
18.3 Line Protection
Secondary protection components can be added to the line interface circuitry to provide lightning surge and AC power-cross immunity. For additional information on the different electrical safety standards and specific applications circuit recommendations, refer to Application Note AN034, Secondary Line Protection for T1 and E1 Cards.
52
DS450PP3
CS61880
19. CHARACTERISTICS AND SPECIFICATIONS 19.1 Absolute Maximum Ratings
CAUTION: Operations at or beyond these limits may result in permanent damage to the device. Normal operation is not guaranteed at these extremes. Parameter DC Supply (referenced to RGND = TGND = 0V) DC Supply Input Voltage, Any Digital Pin except CBLSEL, MODE and LOOP(n) pins (referenced to GNDIO = 0V) Input Voltage CBLSEL, MODE & LOOP(n) Pins (referenced to GNDIO = 0V) Input voltage, RTIP and RRING Pins ESD voltage, Any pin Input current, Any Pin Maximum Power Dissipation, In package Ambient Operating Temperature Storage Temperature Note 1 Note 2 IIH Pp TA Tstg Symbol RV+ TV+ VCCIO VIH VIH Min. -0.5 GNDIO -0.5 GNDIO -0.5 TGND -0.5 2k -10 -40 -65 Max 4.0 4.0 4.6 5.3 VCCIO +0.5 TV+ +0.5 +10 1.73 85 150 Units V V V V V V V mA W C C
19.2 Recommended Operating Conditions
Parameter DC Supply DC Supply Ambient operating Temperature Power Consumption, E1 Mode, 75 line load Power Consumption, E1 Mode, 120 line load Notes 3, 4, 5 Notes 3, 4, 5 Symbol RV+, TV+ VCCIO TA
-
Min. 3.135 3.135 -40 -
Typ 3.3 3.3 25 660 640
Max 3.465 3.465 85 1040 950
Units V V C mW mW
Notes: 1. Human Body Model 2. Transient current of up to 100 mA will not cause SCR latch-up. Also TTIP, TRING, TV+ and TGND can withstand a continuous current of 100 mA. 3. Power consumption while driving line load over the full operating temperature and power supply voltage range. Includes all IC channels and loads. Digital inputs are within 10% of the supply rails and digital outputs are driving a 50 pF capacitive load. 4. Typical consumption corresponds to 50% ones density for at 3.3 V. 5. Maximum consumption corresponds to 100% ones density at 3.465 V. 6. This specification guarantees TTL compatibility (VOH = 2.4 V @ IOUT = -400 A). 7. Output drivers are TTL compatible. 8. Pulse amplitude measured at the output of the transformer across a 75 load. 9. Pulse amplitude measured at the output of the transformer across a 120 load.
DS450PP3
53
CS61880
19.3 Digital Characteristics
(TA = -40 C to 85 C; TV+, RV+ = 3.3 V 5%; GND = 0 V)
Parameter High-Level Input Voltage Low-Level Input Voltage LOOP[7:0] Low-Level Input Voltage LOOP[7:0] Mid-Level Input Voltage LOOP[7:0] High-Level Input Voltage High-Level Output Voltage IOUT = -400 A Low-Level Output Voltage IOUT = 1.6 mA Input Leakage Current Input leakage for LOOP pins Notes 6, 7 Notes 6, 7 Note 6 Note 6 Symbol VIH VIL VIHL VIHM VIHH VOH VOL Min. 2.0 2/3 VCCIO +0.2 2.4 -10 -150 Typ Max 0.8 1/3 VCCIO-0.2 0.4 +10 +150 Units V V V V V V V A A
1/3 VCCIO +0.2 1/2 VCCIO 2/3 VCCIO-0.2
19.4 Transmitter Analog Characteristics
(TA = -40 C to 85 C; TV+, RV+ = 3.3 V 5%; GND = 0 V)
Parameter Output Pulse Amplitudes Notes 8, 9, 11 E1 75 E1 120 Min. 2.14 2.7 0.95 0.95 -0.3 -0.237 -14 -14 -14 Typ 2.37 3.0 -20 -19 -18 0.010 0.009 0.007 0.015 Max 2.6 3.3 1.05 1.05 0.3 0.237 0.020 0.025 0.025 0.050 50 V V dB Units V V
Ratio of Positive to Negative pulses Notes 8, 9, 11 Amplitude at center of pulse interval Width at 50% of nominal amplitude Pulse Amplitude of a space Transmit Return Loss Notes 10, 11, 12 Jitter Added by the Transmitter Notes 10, 13 Transmitter Short Circuit Current per channel E1 120 E1 75 51 kHz to 102 kHz 102 kH to 2048 kHz 2048 kHz to 3072 kHz 10 Hz - 8 kHz 8 kHz - 40 kHz 10 Hz - 40 kHz Broad Band
UI
mA RMS
54
DS450PP3
CS61880
19.5 Receiver Analog Characteristics
(TA = -40 C to 85 C; TV+, RV+ = 3.3 V 5%; GND = 0 V))
Parameter Allowable Cable Attenuation @ 1024 kHz RTIP/RRING Input Impedance (Internal Line matching mode) Note 10 RTIP/RRING Input Impedance (External Line matching mode) Note 10 Receiver Dynamic Range Signal to Noise margin (Per G.703, O151 @ 6 dB cable Atten). Receiver Squelch Level LOS Threshold LOS Hysteresis Data Decision Threshold Note 10 Input Jitter Tolerance Notes 10, 14, 16 Input Return Loss Notes 10, 11, 12 1 Hz - 1.8 Hz 20 Hz - 2.4 kHz 18 kHz - 100 kHz 51 kHz - 102 kHz 102 kHz - 2048 kHz 2048 kHz - 3072 kHz 41 18 1.5 0.2 -18 -18 -18 E1 120 Load E1 75 Load E1 120 Load E1 75 Load Min. 0.5 Typ 13k 50 13k 13k -18 150 200 50 50 -28 -30 -27 59 Max - 12 Units dB
Vp dB mV mV mV % of peak UI
dB
Notes: 10. Parameters guaranteed by design and characterization. 11. Using components on the CDB61880 evaluation board in Internal Match Impedance Mode. 12. Return loss = 20log10 ABS((Z1 + Z0) / (Z1 - Z0)) where Z1 - impedance of the transmitter or receiver, and Z0 = cable impedance. 13. Assuming that jitter free clock is input to TCLK. 14. Jitter tolerance for 6 dB input signal levels. Jitter tolerance increases at lower frequencies. HDB3 coders enabled. 15. In Data Recovery Mode. 16. Jitter Attenuator in the receive path.
DS450PP3
55
CS61880
19.6 Jitter Attenuator Characteristics
(TA = -40 C to 85 C; TV+, RV+ = 3.3 V 5%; GND = 0 V)
Parameter Jitter Attenuator Corner Frequency Note 10, 18 (Depends on JACF Bit in host mode) E1 Jitter Attenuation Note 10, 17 Attenuator Input Jitter Tolerance before FIFO over flow and under flow Note 10 Delay through Jitter Attenuator Only Note 10 Intrinsic Jitter in Remote Loopback 3 Hz to 40 Hz 400 Hz to 100 kHz 32-bit FIFO 64-bit FIFO 32-bit FIFO 64-bit FIFO Notes 10, 16 Min. + 0.5 -19.5 Typ 1.25 2.50 24 56 16 32 Max 0.11 Units Hz
dB UI UI UI UI UI
Notes: 17. Attenuation measured with sinusoidal input filter equal to 3/4 of measured jitter tolerance. Circuit attenuates jitter at 20 dB/decade above the corner frequency. Output jitter can increase significantly when more than 28 UI's are input to the attenuator. 18. Measurement is not effected by the position of the Jitter Attenuator.
+ 10
+ 0.5 0 -6 - 10
ITU G.736
Attenuation in dB
- 19.5 - 20
- 30
- 40
TYP. E1 @ 2.5 Hz CF
- 50
- 60
TYP. E1 @ 1.25 Hz CF
- 70 1 2 10 20 40 57 100 400 1K 1.4K 10K 100K
Frequency in Hz
Figure 18. Jitter Transfer Characteristic vs. G.736 & TBR 12/13
56
DS450PP3
CS61880
1000
300
TYP. E1 Performance
138 100
PEAK TO PEAK JITTER (UI)
28 18 10
1.5 1 .4 .2 .1 1 1.8 4.9 10 20
ITU G.823
100
300
1k
2.4k
10k 18k
100k
FREQUENCY IN Hz
Figure 19. Jitter Tolerance Characteristic vs. G.823
DS450PP3
57
CS61880
19.7 Master Clock Switching Characteristics
Parameter MASTER CLOCK (MCLK) Master Clock Frequency Master Clock Tolerance Master Clock Duty Cycle MCLK -100 40 50 2.048 +100 60 MHz ppm % Symbol Min. Typ Max Units
19.8 Transmit Switching Characteristics
Parameter TCLK Frequency TPOS/TNEG Pulse Width (RZ Mode) TCLK Tolerance (NRZ Mode) TCLK Duty Cycle TCLK Pulse Width TCLK Burst Rate TCLK Falling to TPOS/TNEG Hold time (NRZ Mode) TXOE Asserted Low to TX Driver HIGH-Z TCLK Held Low to Driver HIGH-Z Note 20 Note 10 tsu2 th2 TPOS/TNEG to TCLK Falling Setup Time (NRZ Mode) tpwh2/tpw2 Symbol 1/tpw2 Min. 236 -50 20 25 25 8 Typ 2.048 244 12 Max 252 50 90 20 1 20 Units MHz ns PPM % ns MHz ns ns s s
19.9 Receive Switching Characteristics
Parameter RCLK Duty Cycle RCLK Pulse Width RPOS/RNEG Pulse Width (RZ Mode) RPOS/RNEG to RCLK rising setup time RPOS/RNEG to RCLK hold time RPOS/RNEG Output to RCLK Output (RZ Mode) Rise/Fall Time, RPOS, RNEG, RCLK, LOS outputs Notes: 19. Output load capacitance = 50 pF. 20. MCLK is not active. Note 10 Note 10 Note 10 Note 10 Note 10 Note 10 Note 19 tr, tf tsu th Symbol Min. 40 196 200 200 200 Typ 50 244 244 244 244 10 85 Max 60 328 300 Units % ns ns ns ns ns ns
58
DS450PP3
CS61880
RCLK
tsu
RPOS/RNEG CLKE = 1 RPOS/RNEG CLKE = 0
th
tsu
th
Figure 20. Recovered Clock and Data Switching Characteristics
tpw2 tpwh2 TCLK tsu2 th2
TPOS/TNEG
Figure 21. Transmit Clock and Data Switching Characteristics
tr 90% Any Digital Output 10%
Figure 22. Signal Rise and Fall Characteristics
tf 90% 10%
DS450PP3
59
CS61880
19.10 Switching Characteristics - Serial Port
Parameter SDI to SCLK Setup Time SCLK to SDI Hold Time SCLK Low Time SCLK High Time SCLK Rise and Fall Time CS to SCLK Setup Time SCLK to CS Hold Time CS Inactive Time SDO Valid to SCLK CS to SDO High Z Note 21 Note 21 Symbol tdc tcdh tcl tch tr, tf tcc tcch tcwh tcdv tcdz Min. Typ. 20 20 50 50 15 20 20 70 60 50 Max Unit ns ns ns ns ns ns ns ns ns ns
Notes: 21. If SPOL = 0, then CS should return high no sooner than 20 ns after the 16 th rising edge of SCLK during a serial port read.
CS SCLK SDI SDO CLKE=0 SDO CLKE=1 LAST ADDR BIT
tcdv
D0 D1 D6 D7
tcdz
tcdv
D0 D1 D6 D7 HIGH Z
Figure 23. Serial Port Read Timing Diagram
tcwh
CS
tcc
SCLK
tch
tcl
tcch
tdc
SDI LSB
tcdh
LSB
tcdh
MSB
Figure 24. Serial Port Write Timing Diagram
60
DS450PP3
CS61880
19.11 Switching Characteristics - Parallel Port (Multiplexed Mode)
Parameter Pulse Width AS or ALE High Muxed Address Setup Time to AS or ALE Low Muxed Address Hold Time Delay Time AS or ALE to WR, RD or DS CS & R/W Setup Time Before WR, RD or DS Low CS & R/W Hold Time Pulse Width, WR, RD, or DS Write Data Setup Time Write Data Hold Time Output Data Delay Time from RD or DS Low Read Data Hold Time Delay Time WR, RD, or DS to ALE or AS Rise WR or RD Low to RDY Low WR or RD Low to RDY High WR or RD High to RDY HIGH-Z DS Low to ACK High DS Low to ACK Low DS High to ACK HIGH-Z Ref. # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Min. 25 10 5 5 0 0 70 30 30 5 30 Typ. Max 100 55 100 40 65 100 40 Unit ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns
DS450PP3
61
CS61880
1
ALE 12 4 7
WR 5 CS 2 3 6
8
9 Write Data
D[7:0]
ADDRESS
15 HIGH-Z RDY 13 14 HIGH-Z
Figure 25. Parallel Port Timing - Write; Intel(R) Multiplexed Address / Data Bus Mode
1
ALE 12 4 7
RD 5 CS 6
2 D[7:0]
3
10
11
ADDRESS
Read Data
15 14
HIGH-Z RDY 13
HIGH-Z
Figure 26. Parallel Port Timing - Read; Intel Multiplexed Address / Data Bus Mode
62
DS450PP3
CS61880
1
AS 12 DS 4 7
R/W 5 CS 6
2
3
8
9
D[7:0]
ADDRESS 17 HIGH-Z
Write Data 18 HIGH-Z 16
ACK
Figure 27. Parallel Port Timing - Write; Motorola(R) Multiplexed Address / Data Bus Mode
1
AS 12 DS 4 7
R/W 5 CS 6
2
3
10
11
D[7:0]
ADDRESS 17 HIGH-Z
Read Data 18 HIGH-Z 16
ACK
Figure 28. Parallel Port Timing - Read; Motorola Multiplexed Address / Data Bus Mode
DS450PP3
63
CS61880
19.12 Switching Characteristics- Parallel Port (Non-Multiplexed Mode)
Parameter Address Setup Time to WR, RD or DS Low Address Hold Time CS & R/W Setup Time Before WR, RD or DS Low CS & R/W Hold Time Pulse Width, WR, RD, or DS Write Data Setup Time Write Data Hold Time Output Data Delay Time from RD or DS Read Data Hold Time WR or RD Low to RDY Low WR, RD or DS Low to RDY High WR, RD or DS High to RDY HIGH-Z DS Low to ACK High DS Low to ACK Low DS High to ACK HIGH-Z Ref. # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Min. 10 5 0 0 70 30 30 5 Typ. Max 100 55 100 40 65 100 40 Unit ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns
64
DS450PP3
CS61880
1
2
A[4:0]
ADDRESS
ALE
(pulled high) 5
WR 3 4
CS 6 7
D[7:0]
Write Data
11 HIGH-Z RDY 10
12 HIGH-Z
Figure 29. Parallel Port Timing - Write; Intel Non-Multiplexed Address / Data Bus Mode
1
2
A[4:0]
ADDRESS
ALE
(pulled high) 5
RD 3 CS 8 9 4
D[7:0]
Read Data
11 HIGH-Z RDY 10
12 HIGH-Z
Figure 30. Parallel Port Timing - Read; Intel Non-Multiplexed Address / Data Bus Mode
DS450PP3
65
CS61880
1
2
A[4:0]
ADDRESS
AS
(pulled high) 5
DS
R/W 3 CS 6 7 4
D[7:0]
Write Data
14 HIGH-Z ACK 13
15 HIGH-Z
Figure 31. Parallel Port Timing - Write; Motorola Non-Multiplexed Address / Data Bus Mode
1
2
A[4:0]
ADDRESS
AS
(pulled high) 5
DS
R/W 3 CS 8 9 4
D[7:0]
Read Data
14 HIGH-Z ACK 13 15 HIGH-Z
Figure 32. Parallel Port Timing - Read; Motorola Non-Multiplexed Address / Data Bus Mode
66
DS450PP3
CS61880
19.13 Switching Characteristics - JTAG
Parameter Cycle Time TMS/TDI to TCK Rising Setup Time TCK Rising to TMS/TDI Hold Time TCK Falling to TDO Valid Symbol tcyc tsu th tdv Min. 200 50 50 Max 70 Units ns ns ns ns
tcyc
TCK tsu TMS TDI TDO tdv th
Figure 33. JTAG Switching Characteristics
DS450PP3
67
CS61880
20. COMPLIANT RECOMMENDATIONS AND SPECIFICATIONS
ETSI ETS 300-011 ETSI ETS 300-166 ETSI ETS 300-233 ETSI TBR 12/13 IEEE 1149.1 ITU-T I.431 ITU-T G.703 ITU-T G.704 ITU-T G.706 ITU-T G.732 ITU-T G.735 ITU-T G.736 ITU-T G.742 ITU-T G.772 ITU-T G.775 ITU-T G.783 ITU-T G.823 ITU-T O.151 OFTEL OTR-001
68
DS450PP3
CS61880
21. 160-BALL FBGA PACKAGE DIMENSIONS
Figure 34. 160-Ball FBGA Package Drawing
DS450PP3
69
CS61880
22. 144-PIN LQFP PACKAGE DIMENSIONS
E E1
D D1
1 e A1 L B A
Figure 35. 144-Pin LQFP Package Drawing Table 16. 144-Pin Package Dimensions INCHES MILLIMETERS MIN NOM MAX MIN NOM --0.55 0.063 --1.40 0.002 0.004 0.006 0.05 0.10 0.007 0.008 0.011 0.17 0.20 0.854 0.866 BSC 0.878 21.70 22.0 BSC 0.783 0.787 BSC 0.791 19.90 20.0 BSC 0.854 0.866 BSC 0.878 21.70 22.0 BSC 0.783 0.787 BSC 0.791 19.90 20.0 BSC 0.016 0.020 0.024 0.40 0.50 BSC 0.000 4 7.000 0.00 4 L 0.018 0.024 0.030 0.45 0.60 * Nominal pin pitch is 0.50 mm Controlling dimension is mm. JEDEC Designation: MS022 DIM A A1 B D D1 E E1 e* MAX 1.60 0.15 0.27 22.30 20.10 22.30 20.10 0.60 7.00 0.75
70
DS450PP3


▲Up To Search▲   

 
Price & Availability of CS61880-IB

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X